Laserfiche WebLink
' � l <br /> Pro ect Summa�/ Jo6: 2575A sf ADS 2017 <br /> 1 •� Date: 7/6/2017 <br /> upper floor � Bv: oa�e <br /> . BAYONET PLUIIABING COOLING HEATING. <br /> ' • - e s <br /> For. Lennar Homes I <br /> Notes: <br /> , - e • s <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 11004 Btuh Structure 17080 Btuh <br /> Ducts 1846 Btuh Ducts 2137 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12850 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19217 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2266 Btuh <br /> Ducts 379 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> ` Heating Cooling (none) <br /> Area(ft2) 1491 1491 Equipment latent load 2645 Btuh <br /> Volume(ft') 11928 11928 <br /> , Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21862 Btuh <br /> Equiv.AVF(cfm) 54 29 Req. total capacity at 0.85 SHR 1.9 ton <br /> Heating Equipment Summary - Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024230-21 Cond 14HPX-024-230-21 <br /> AHRI ref 10258598 - Coil CBA27UHE-024230'`++TDR <br /> AHRI ref 10258598. <br /> Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 �F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.062 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point= 17°F <br /> Backup: - <br /> Input= 3 kW, Output= 11787 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> W�'1 �'ttSO'ft' 2017-JuF06 06:32:07 <br /> �Ag Right-Suite�Universal 2017 77.0.23 RSU05714 Page 2 <br /> .ith CBA27UHE AH's\2575A1 sf ADS drawn 1.S2.rup Calc=MJB Front Door faces: S <br />