Laserfiche WebLink
.,� i <br /> �_ _ � _ _ _ <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method � <br /> i <br /> Project Name: 3127B sfADS BuilderName: CENNAR HOMES � <br /> str�et: 6503 Paden Wheel Street Pertnit Office: Clty„gf��e�hyrhills ; <br /> City,State,Zip: ,FL, Permit Number ��3 <br /> Owner LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. WaII Types(2907 1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4.1 13�9.80 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ft2 <br /> 4 Number of Bedrooms 5 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1772.00 ft <br /> 6. Conditioned floor area above grade(ft2) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft' <br /> 11.Ducts R ftZ <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 302.4 <br /> a. U-Factor� Dbl,U=0.54 162.68 ft2 b.Sup. Attic, Ret:2nd Floor,AH:2nd Floor 6 323 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 117.00 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 86.67 ft' _ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency � <br /> d. U-Factor� N/A ft2 a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4.220 ft. � <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (3181.0 sqft.) Insulation Area EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft� b. Conservation features <br /> b.Floor Over Other Space R=0.0 1409.00 ft' None <br /> c.other(see details) R= 260.00 ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 90 98 <br /> Glass/Floor Area: 0.117 - PASS <br /> Total Baseline Loads. 92.81 <br />� I hereby certify that the plans and specifications covered by Review of the plans and ��''C���7'��.� . <br /> this calculation are in compliance with the Florida Energy specifications covered by this �v d���O�,. . <br /> Code. calculation indicates compliance ���i,r��;`,, Y:;A�,.,`„o�,`t�. <br /> �a�e �G�l�rc% with the Florida Energy Code. � -1rr��,�'.��%�:::.a'.,•'.,��;t O <br /> < �"::s" >::,�t+�., .� <br /> PREPARED BY: Before construction is completed w. �-• � <br /> DATE. this buildin will be ins ected for �" `�"'"�" -- � � ' <br /> 9 P t7 �.�,,� �+, <br /> compliance with Section 553.908 �� � a <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. , � � ; <br /> Y � 9, 9 P ��' �°s. i <br /> with the Florida Energy Code. _ �'42>yy�;� , <br />� OWNER/AGENT. BUILDIN OFFICIAL. <br /> DATE: DATE: �` <br /> I <br /> - Compliance requires certification by e air handler unit manufacturer that the air handler enclosure qualifies as 1 <br /> certified factory-sealed in accordance with R403.2.2.1. �. I <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, � <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. <br /> 7/10/2017 12:03 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 ' <br />\ <br />