My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18786
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18786
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2018 10:30:42 AM
Creation date
7/30/2018 10:30:40 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18786
Building Department - Name
LENNAR HOMES LLC
Address
6503 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� , � � <br /> � - I <br /> FORM R405-2014 , I <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method I <br /> Project Name: 3127B sf ADS Builder Name: LENNAR HOMES � <br /> street: 6503 Paden Wheel Street Permit office. City of Zephyrhills a <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner• LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) � <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4 1 1309.80 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ <br /> 4 Number of Bedrooms 5 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z � <br /> a.Under Attic(Vented) R=30.0 1772.00 ft <br /> 6. Conditioned floor area above grade(ft2) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11 Ducts R ftZ <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 302.4 � <br /> a. U-Factor Dbl,U=0.54 162.68 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323 <br /> SHGC: SHGC=0.31 � <br /> b. U-Factor Dbl,U=0.56 117.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor• Dbl,U=0.56 86.67 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ft= a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 , <br /> Area Weighted Average Overhang Depth. 4.220 ft. <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems <br /> 8. Floor Types (3181.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.850 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1409.00 ft2 None <br /> c.other(see details) R= 260.00 ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.117 Total Proposed Modified Loads: 90.98 PASS <br /> Total Baseline Loads. 92.81 <br /> - . � <br /> I hereb certi that the lans and s ecifications covered b Review of the lans and 'Y���"` ' <br /> Y fY P P Y P ��:. ,4��,. <br /> this calculation are in compliance with the Florida Energy specifications covered by this �. , , �= p�,,, <br /> . r <br /> Code. calculation indicates compliance ���i,,;'' '�:=,�``�.�. � <br /> with the Florida Energy Code. C.��rrru�:`°%;:���.�•` "��a f0. <br /> +`�a <br /> /,,� /. �"�r?o�i:fiu., <br /> PREPARED BY: �aV� �Wl{�l�Vl Befare construction is completed � � " ''�'`-* <br /> ��� C7 <br /> DATE: this building will be inspected for �ry�,;��; . •:�. I <br /> compliance with Section 553.908 * <br /> �� �•. <br /> Florida Statutes. :r� �� � <br /> I hereby certify that this building,as designed, is in compliance �.� - .. ,��.- i <br /> with the Florida Energy Code. �D yyfi'�' <br />' � <br /> OWNER/AGENT. BUILDING OFFICIAL. <br /> DATE. DATE: � <br /> - Compliance requires certification.by the air handler unit manufacturer that the air handler enclosure qualifies as_ <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, , <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house. <br /> 7/10/2017 12:03 PM EnergyGauge�USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 5 � <br />
The URL can be used to link to this page
Your browser does not support the video tag.