My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18788
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18788
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2018 10:32:47 AM
Creation date
7/30/2018 10:32:45 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18788
Building Department - Name
LENNAR HOMES LLC
Address
6515 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida.Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 4259A sf ADS Builder Name: Lennar Homes <br /> street: 6515 Paden Wheel Street Permit ot�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br />' Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4 1 1682.30 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ft2 <br /> 4 Number of Bedrooms 6 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2347.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 4259 b.Knee Wall(Vented) R=30.0 152.00 ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� <br /> 11 Ducts R ft2 <br />' 7. Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 <br /> a. U-Factor• Dbl,U=0.54 298.01 ftz b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 <br /> SHGC: SHGC=0.31 � <br /> b. U-Factor Dbl,U=�.56 98.69 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.58 72.00 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• other(see details) 50.00 ft2 a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4 720 ft. <br /> Area Weighted Average SHGC: 0.305 14 Hot water systems <br />� 8. Floor Types (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.950 <br /> a.Floor Over Other Space R=0.0 2060.00 ft� b. Conservation features <br /> � b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ft� None <br /> c.other(see details) R= 287.00 ft' 15.Credits Pstat <br /> Glass/Floor Area: 0.122 Total Proposed Modified Loads. 120.70 pASS <br /> Total Baseline Loads: 122.51 . <br /> II hereby certify that the plans and specifications covered by Review of the plans and �'C�:ST��., , <br /> O ,.. <br /> this calculation are in compliance with the Florida Energy specifications covered by this � �,�4;�p <br /> Code. calculation indicates compliance 4j�i„�°''� '""�� �. <br /> with the Florida Energy Code. � � ��rf;;f�'>;;;'_:'_�;:�*'�``�ti O <br /> �G��e ��I G�l � . .,,� �.�,�;�.__ .� <br /> PREPARED BY: � Before construction is completed w. �.�� � <br /> f�'. ;.. 3,._ .._ <br /> DATE: this building will be inspected for �. t.;}��. , � : <br /> compliance with Section 553.908 � � '�_ � :�.. <br /> Florida Statutes. � . . � <br /> I hereby certify that this building,as designed, is in compliance <�, • �g.. . <br /> with the Florida Energy Code. �dD�.WE`� <br /> OWNER/AGENT: BUILDING OF�I�IAL. <br /> DATE: DATE. � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br />, certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house. _ <br /> 7/6/2017 7:45 AM EnergyGaugeO USA-FlaRes2014 Section R4�5.4 1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.