Laserfiche WebLink
� 4 <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 4259A sf ADS Builder Name: Lennar Homes _ <br /> street: 6515 Paden Wheel Street Permit otfice: City of Zephyrhills <br /> City,State,Zip. ,FL, Permit Number• <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874 70 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ftZ <br /> 3. Number of units,if multiple family 1 - c.Frame-Wood,Adjacent R=11.0 560.00 ft2 <br /> 4. Number of Bedrooms 6 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area z <br /> a.Under Attic(Vented) R=30.0 2347.00 ft <br /> 6. Conditioned floor area above grade(ftz) 4259 b.Knee Wall(Vented) R=30.0 152.00 ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11 Ducts R ftZ <br /> 7. Windows(518.7 sqft.) Description Area a.Sup.Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 <br /> a. U-Factor Dbl,U=0.54 2g8.01 ftZ b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 98.69 ft' 12•Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.58 72.00 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor other(see details) 50.00 ftZ a.Electric Heat Pump 21.8 HSPF:8.50 <br />' SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4 720 ft. <br /> Area Weighted Average SHGC: 0.305 14.Hot water systems <br /> 8. Floor Types (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br />, a.Floor Over Other Space R=0.0 2060.00 ft2 b. Conservation features <br /> b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ft2 None <br /> c.other(see details) R= 287.00 ft' 15.Credits Pstat <br /> Glass/Floor Area: 0.122 Total Proposed Modified Loads: 120.70 pASS ' <br /> Total Baseline Loads: 122.51 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'C��T.q�, <br /> U ,. <br /> this calculation are in compliance with the Florida Energy specifications covered by this �v , ��.��0. <br /> °,�f� :°=:'.� � <br /> C o d e. c a l c u l a t i o n i n d i c a t e s c o m p l i a n c e r,��r r rt,. , , ,• • <br /> �a�e �C a l�r`c!� �✓ith the Florida Energy Code. �, ur,r,�„r` `•�=� ���„t0 <br /> PREPARED BY� p � �"� � <br /> ,�, �;,..`;:�=;. <br /> Before construction is com leted w � <br />' DATE. this building will be inspected for � ."'���" � � <br /> _ compliance with Section 553.908 ��''� <br /> I hereby certify that this building,as designed, is in compfiance Florida Statutes. �,,�; � <br /> with the Florida Energy Code. �D yyE'�' <br /> OWNER/AGENT. BUILDING OFFICIA <br /> DATE. � DATE. � - <br /> - Compliance requires certifcation by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report conFrming duct leakage to outdoors, , <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 Qn for whole house. I <br /> 7/6/2017 7�45 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />