Laserfiche WebLink
r, _ .� � <br /> FORM R405-2014 . <br />� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida De artment of Business and Professional Re ulation - Residential Performance Method <br /> p 9, <br /> Project Name. 4259A sf ADS Buildet.Name: Lennar Homes <br /> screet: 6515 Paden Wheel Street Permit o�ce: City of Ze�hyrhills <br /> City,State,Zip. ,FL, Permit Number• ?g <br /> Owner Lennar Homes Jurisdiction: 611`6�0 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br />'� 1 New constructionror existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area <br /> a.Frame-Wood Exterior R=11.0 1874.70 ftZ <br /> 2. Single family or multiple family Single-family b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ft' <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ft2 <br /> 4 Number of Bedrooms 6 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2347.00 ft <br /> 6. Conditioned floor area above grade(ft2) 4259 b.Knee Wall(Vented) R=30.0 152.00 ft� <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft' <br /> 11 Ducts R ft� <br /> 7. Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 <br />' a. U-Factor• Dbl,U=0.54 298.01 ftZ b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 gg,gg ff= �2.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.58 72.00 ft= <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• other(see.details) 50.00 ft� a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4 720 ft. <br /> Area Weighted Average SHGC: 0.305 14 Hot water systems <br /> S. Floor Types (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF'0.950 <br /> a.Floor Over Other Space R=0.0 2060.00 ftz b. Conservation features <br />' b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ft2 None <br /> c.other(see details) R= 287.00 ft' 15.Credits Pstat <br /> Glass/FloorArea: 0 122 Total Proposed Modified Loads: 120.70 pASS I' <br /> Total Baseline Loads: 122.51 � <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��`C��T.q�,� , <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' �a �� - O <br /> ��,� ���, <br /> Code. calculation indicates compliance y���,' �_, �..�. �. <br /> with the Florida Energy Code. f�''�..�-�:�'�°:���;ti�O. <br /> J7Q�� �{��lG�l � 117„ .,% . <br /> a;.,�:. -� <br /> PREPARED BY' Before construction is completed ��� �:; � <br /> DATE. this building will be inspected for Lry �,����. � :�; : <br /> compliance with Section 553.908 ��� u � <br /> Florida Statutes. ,�^ "��.�:.. . <br /> I�hereby certify that this building,as designed, is in compliance � - .. c�. . <br /> with the Florida Energy Code. - �4,t')'y}r��� <br /> OWNER/AGENT. BUILDING OFFICIAL. <br /> DATE. DATE: P� <br /> -�-�,�� <br /> - Compliance requires certification by the air handler unit ma ufacturer that the air handler enclosure qualifies as ` <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report conFrming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house. <br /> 7/6/2017 7•45 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />