Laserfiche WebLink
FORM R405-2014 <br /> FLORtDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department af Business and Professional Regulation - Residentia[ Perfarmance Methad <br /> Projeck Name: 9941 B sf ADS 3fon Builder Name: Lennar Hames <br /> street: 36017 Stable Willr Avenue Permit Office: City of Zep�lyrhillS <br /> Gity,State,Zip: ,Fl., Permit Number• <br /> Owner Lennar Homes Jurisdictian: 611600 <br /> Design Location: FL,Tampa County Pasco(Florida Glimate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multipte family 5ingle-famity a.Concrete Slock-Ini Insul,E�erior R=4.1 1454.60 ftz <br /> b.Frame-Waod,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R_ �x <br /> 4. Rlumber of Badrooms 4 d.NtA �_ ft2 <br /> 5. Is this a worst case? Yes 90.Ceiling Types (1936,0 sqft.) Insulation Area z <br /> a.Under Attic(Vented� R=30.0 1936.00 ft <br /> 6. Gonditianed floar area ahave grade{ft�} 1936 b.NtA R= ft2 <br /> Conditioned floor area below grade(ft�) 0 c.N/A R= ftZ <br /> 91,Ducts R ft� <br /> ?. Windows{'15�.3 sqft.} Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 8 387.2 <br /> a. U-Factor Dbl,U=0.54 101.00 ftx <br /> SHGC: SHGC=fl.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft2 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor• Db1,U�0.56 23AQ ft2 <br /> SHGC: SHGC=0.28 13.Heating sys#ems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average StiGG: p,3pg 14.Hot water systems <br /> 8. FloorTypes (1936.0 sqftJ Insulation Area a.Etectric Cap:40 galtons <br /> EF•0.950 <br /> a.Slab-On-Grade Edge lnsulatian R=O.Q 1936.00 ft2 b. Co�servation features <br /> b.N!A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Fioor Area: 0.081 Total Praposed Modi�ed Laads: 62.94 pASS <br /> Tatal Baselirte Loads: 62.65 <br /> I hereby cerfify that the plans and specifications covered by Review af the plans and 'Tk�� " . ; <br /> ' -4�' . ��'�_ .. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ����' '"_- p <br /> Code. calculation indicates compliance '�'+ r,f,`�'' _��.��.�+. <br /> /,,� with the Florida Energy Code. >�rrrri�%:--==�"r;°a*-''ti�� <br /> PREPARED BY' - �aV� �Wl�'(�� Before construction is campleted �c i ' "�" � <br /> DATE: this building wiU be inspected for � . _��f` �. �: <br /> comp(iance with Section 553.908 *,�?��'�--. .; � <br /> I hereb certi that this buildin as desi ned,is in com liance Florida Statutes. .��- <br /> Y fY 9, 9 P � "r�r�, ;.�.. _ �c�. <br /> with fhe Florida Energy Code. � .Ojj y�,� _ <br /> QWNERlAGENT. BUlLDlNG OF CIAL; <br /> DATE: DATE: <br /> - Compliance requires certification hy#he air handler unit manufacturer that the air handler enctosure qualifies as <br /> certified factary�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> #es#repart in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report canfirming duct leakage to outdoors, <br /> tested in accorctance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:24 AM EnergyGauge�USA-FlaRes201Q Sectian R405.4.1 Campliant 5oftware Page 1 of 5 <br />