Search
17-18789
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18789
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2018 10:33:38 AM
Creation date
7/30/2018 10:33:36 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18789
Building Department - Name
LENNAR HOMES LLC
Address
36017 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- r- 4 , <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes <br /> street: 36017 Stable Wilk Avenue Perm�t o��: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• l �,�� <br /> Owner• Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R_ �2 <br /> 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft' <br /> 6. Conditioned floor area above grade(ft� 1936 b.N/A R= ftz <br /> Conditioned floor area below grade(ftZ) 0 �• R= ft <br /> z <br /> 11.Ducts R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft� <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftZ �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor• Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft� a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ff2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.94 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and .��k�E;Sx��,. -,_ <br /> this calculation are in compliance with the Florida Energy specifications covered by this .�� �., ""_�_;�p � <br /> Code. ',,�� �;�� �,_�, <br /> calculation indicates compliance , �'��,;�- ;� -_-a��.�`,re,, . <br /> �"� /. with the Florida Energy Code. t-. �r�,;,��;,;:;;�';�;v�`'„�� <br /> PREPARED BY. �G�l�� f�wlj'l�Vl Before construction is completed '' °'' � <br /> :� ,. r..`1 _``_ �,.,,. <br /> DATE. this building will be inspected for �_ ; �� . ": ,,d . <br /> compliance with Section 553.908 " *����� <br /> �s. -. <br /> : �. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � _Y _ �,� <br /> with the Florida Energy Code. G'pb•�.�� ,. <br /> OWNER/AGENT: BUILDING OFFICIAL: � <br /> DATE. DATE: "�7� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:24 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> !,-� <br />