My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18790
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18790
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2018 10:34:53 AM
Creation date
7/30/2018 10:34:52 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18790
Building Department - Name
LENNAR HOMES LLC
Address
36018 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
%- y <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Rasidential Perfarmance Method <br /> Project Name: 1791A sf ADS Builder Name: Lennar Homes <br /> street: 36018 Stable Wilk Avenue permit office: City of Zephyrhills <br /> Gity,StaEe,Zip; ,FL, Permit htumtaer: ��'��� <br /> owner. �ennar Homes Jurisdiction: 6I 1600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single famity or multiple famity Single-family a.Concrete SIock-Int Insui,Exterior R=4.1 1241.30 ff2 <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R_ gx <br /> 4. Number of Bedroams 4 d•N1A R= ft2 <br /> 5. Is this a worst case? Yes 'il1•Ceiling Types (1817.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30A 1817A0 ft <br /> 6. Conditioned Hoor area above grade{ft�} 1897 b.NIA R= ft2 <br /> Conditioned floor area below grade(ftx) p c.N/A R= ftx <br /> 11 DuCts R ft� <br /> 7. Windows{143.3 sqft.) Description Area a.Sup:Attic,F2et:Main,AH:Main 6 363..4 <br /> a. U-Factor: Dbl, U=0.54 87.00 ft2 <br /> SNGC: SHGC=d.31 <br /> b. U-Factor D61,U=0.56 33.33 ft2 12.Cooiing systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor. Dbl,U=0.56 23.OQ ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Elect�ic Heat Pump 26.d HSPE:8.50 <br /> SHGG: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: {}.308 14.Hot water systems <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 ga(lons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulatian R=Q.Q 1817.Q4 ft2 b. Conservation features <br /> b.NlA R= ft2 None <br /> c.N!A R= ftx ��.Credits Pstat <br /> Glass/Floor Area: 0.079 <br /> Tatal Praposed Modified Loads: 58.08 pASS <br /> Tatal BaseEine Laads: 58.91 <br /> I hereby certify that the plans anc!specifications covered by Review of the plans and ��'t�:�7'.r��;. .: <br /> this calculation are in compliance with ihe Flarida Energy specificatians covered by this ,�'Q. '" __.��:,,'�O . � <br /> Cade. calculatian indicates compliance I �'v±'f,,,�''� `"'��:��•�+. <br /> �aV� �J�G�w with the Florida Energy Code. �F+� ruri<�`�,�;;;=s�,;:a�`ti,�Or� <br /> f'REPARED BY: � '"" " <br /> �U� YC Before construction is completed � � - �•: ''�� : � <br /> DATE; this bui(ding wi([be inspeeted for � "`':1���. : �;,� ; <br /> compliance with Section 553.908 ,� ��. ; -�_ <br /> I hereb certi that this buildin as desi ned, is in m liance Florida Statutes. '. .�- , <br /> Y fY 9� 9 P '�` - . , • �. ., <br /> wifh the Flarida Energy Code. �a!;jr�;fi��:. <br /> OWNER/AGENT: BUILDING OF 1AL: <br /> DATE. DATE: ' <br /> - Compliance requires certification by t e air handler unit manufacturer that the air handler enclosure quatifies as <br /> certified factary-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accardance with R402.4.9.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is nat greater than OA30 Qn for who[e hause. <br /> 7/14/2017 9:12 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Campliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.