My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18790
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18790
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2018 10:34:53 AM
Creation date
7/30/2018 10:34:52 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18790
Building Department - Name
LENNAR HOMES LLC
Address
36018 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; y <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />' Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1791A sf ADS Builder Name: Lennar Homes <br /> street: 36018 Stable Wilk Avenue Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County�� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1241.30 ftz <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4 Number of Bedrooms 4 d.N/A R= ftZ <br /> 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 <br />' 6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 - c.N/A R= ft2 <br /> 11.Ducts R ftZ <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor Dbl,U=0.54 87.00 ft� <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor. Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr E�ciency <br /> d. U-Factor: N/A ft' a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> 8. FloorTypes (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft= 15.Credits Pstat <br /> Glass/Floor Area: 0.079 <br /> Total Proposed Modified Loads: 58.08 pASS <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ;O��I�E S�AT,� .. <br /> this calculation are in compliance with the Florida Energy specifications covered by this . "__�� ,;-p � <br /> q,� �w�.r :_�{+, . <br /> Code. calculation indicates compliance �, �;,, � , =,?=,���``�.� <br /> �ave /� /, with the Florida Energy Code. F+' +irrr.�"�. -;`:=�;.�';,•�='�titi 0 �. , <br /> PREPARED BY: �w����'c Before construction is completed 'r�. � '' " ' �' � <br /> DATE: this building will be inspected for � j�hrIf- " O <br /> compliance with Section 553.908 ' *, . � � .- * � <br /> __�;�.+�::- - <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. '_ ' � <br /> with the Florida Energy Code. G'OOrj `'C�� <br /> 1NE:,• - <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: � � � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory,sealed in accordance with R403.2.2.1. ' <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance wifh R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:12 AM. EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.