Laserfiche WebLink
r 5 <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1791A sf ADS Builder Name: Lennar Homes <br /> streec: 36018 Stable Wilk Avenue Permit o�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1817.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1817 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl,U=0.54 87.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft� 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft� a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. FloorTypes (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftz b. Conservation features <br /> b.N/A R= ft� None <br /> c.N/A R= ft� 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.08 pASS <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and -- 'T�:Sx,� , <br /> Q�`' ,�'� •,. <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ,� '�� �., p�, . <br /> Code. calculation indicates compliance �,,,''' _=�':��. .+s+ <br /> � , ';�� �,� ,�'. : <br /> �" with the Florida Ener Code. �+ fun,; �• "�"',��'��ti <br /> PREPARED BY �G�V� f���GYG 9Y �`'� ��� `` � <br /> Before construction is completed 'r i �� '''r "��'' " <br /> DATE: this building will be inspected for � -f';�C�i _- `�:� <br /> compliance with Section 553.908 ' � -=��' :-,,� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .�, : � <br /> with the Florida Energy Code. C�Dy�_'1'��_- <br /> OWNER/AGENT: BUILDING O ICIAL: <br /> DATE: DATE: ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:12 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software -- Page 1 of 4 <br />