, 1
<br /> . y
<br /> FORM R405-2014 '
<br /> I
<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION '
<br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method . �
<br /> ;
<br /> Project Name: 257561 sf ADS 2017 Builder Name: Lennar Homes 0�37 '
<br /> Street: 3(t3�' Moulden Hollow Drive Permit o�ice: C' of Zephyrhills
<br /> City,State,Zip. ,FL, Permit Number:���77
<br /> Owner Lennar Homes Jurisdiction: 6116U1�
<br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) �
<br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area �
<br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
<br /> b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ft2
<br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft'
<br /> 4. Number of Bedrooms 4 d.N/A R= ft�
<br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area 2 '
<br /> a.Under Attic(Vented) R=30.0 1489.00 ft
<br /> 6. Conditioned floor area above grade(ftZ) 2582 b.N/A R= ftZ
<br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 !
<br /> 11 Ducts R ft'
<br /> 7. Windows(175.6 sqft.) Description Area a.Sup.Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
<br /> a. U-Factor. Dbl,U=0.54 71.25 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 �
<br /> SHGC: SHGC=0.31 ''
<br /> b. U-Factor Dbl,U=0.56 71.00 ft' �2•Cooling systems k6tu/hr Efficiency '
<br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 ,
<br /> b.Central Unit 25.2 SEER:16.00
<br /> i c. U-Factor: Dbl,U=0.56 33.33 ft' i ,
<br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr E�ciency I
<br /> d. U-Factor N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50
<br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 i
<br /> Area Weighted Average Overhang Depth: 1 190 ft.
<br /> Area Weighted Average SHGC: 0.300 14 Hot water systems '
<br /> 8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons
<br /> EF'0.950 i
<br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features i
<br /> b.Floor Over Other Space R=0.0 1049.00 ftZ None
<br /> c.other(see details) R= 440.00 ft' 15.Credits Pstat
<br /> 1
<br /> Total Proposed Modified Loads. 74.47 � A �+�+
<br /> Glass/Floor Area: 0.068 /�-���7�7 �
<br /> Total Baseline Loads: 74 41
<br /> I hereby certify that the plans and specifications covered by Review of the plans and ��•�:$rA�•.�,., ;
<br /> this calculation are in compliance with the Florida Energy specifications covered by this �„� ,- _a .�, �}�,, ,
<br /> Code. calculation indicates compliance � r,,,r�s- r�;_�;�� �
<br /> ., . ,
<br /> �•�trf;rr��"',,;.;',-.:z'',�.�'�`°�
<br /> �ave �Gal�r'cl� with the Florida Energy Code. � �,�,,,,�ti O
<br /> PREPARED BY. Before construction is completed w� • '�'� � �
<br /> this buildin will be ins ected for � � '�" r. �
<br /> i DATE: 9 P t7 ; �'�fr��:� �. . I
<br />, compliance with Section 553.908 .�� °. �
<br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � �
<br /> Y fY 9, 9 P ��, �tij°s
<br /> with the Florida Energy Code. _ �D yyE'T�' "
<br /> OWNER/AGENT: BUILDING OFF CIAL. ,
<br /> I DATE. DATE: "" � �
<br />' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as -
<br /> certified factory-sealed in accordance with R403.2.2.1.
<br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
<br /> test report in accordance with R402.4.1.2.
<br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ,
<br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house.
<br /> 8l14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
<br /> � I
<br />
|