My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18877
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18877
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:30:03 AM
Creation date
7/31/2018 11:30:01 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-18877
Building Department - Name
LENNAR HOMES LLC
Address
3185 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I � 5 <br /> FORM R405-2014 i <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method � <br /> Project Name. 2575B1 sf ADS 2017 Builder Name: Lennar Homes ��3� i <br /> street: 3�0 c5� Moulden Hollow Drive Permit Office: Cltv of Zephyrhills ' <br /> City,State,Zip. ,FL, Permit Number: ZFf g��J <br /> Owner Cennar Homes Jurisdiction: 611600 � <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> ' 1 New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area � <br /> a.Frame-Wood,Exterior R=11.0 1264.00 ft' � <br /> 2. Single family or multiple family Single-family b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ft' <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft� j <br /> 4 Number of Bedrooms 4 d.N/A R- ft� <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area Z i <br /> a.Under Attic(Vented) R=30.0 1489.00 ft <br /> 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft� <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 <br /> 11 Ducts R ft' <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 i <br /> a. U-Factor Dbl, U=0.54 7125 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor• Dbl, U=0.56 71.00 ftz 12.Cooling systems kBtu/hr Efficiency � <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 33.33 ft� I <br /> SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency i <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 � <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth. 1 190 ft. <br /> Area Weighted Average SHGC: 0.300 14 Hot water systems I <br /> 8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons i <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features � <br /> b.Floor Over Other Space R=0.0 1049.00 ft' None � <br /> c.other(see details) R= 440.00 ftz 15.Credits Pstat <br /> Total Proposed Modified Loads. 74.47 pASS + <br /> Glass/Floor Area: 0.068 <br /> Total Baseline Loads: 74.41 i <br /> I <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'��T',�Ir� ! <br /> this calculation are in compliance with the Florida Energy specifications covered by this ^�v • 0,�,. . <br /> Code. calculation indicates compliance �'�/i/r��;lT� �=�w.;,.�`.t„� ; <br /> �' t. ' •--::`�wt t" <br />� - �a�e ���G/. with the Florida Energy Code. �+ ��rrrrr: :���,:,;::�:�•°;.�,;,,, O <br /> Q -'i��.' ,y i <br /> PREPARED BY r� Before construction is completed w. - ;�'"� ; <br /> i DATE. this building will be inspected for �. "`������ � <br /> compliance with Section 553.908 * �'� �. � a�: ��. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � " " � . <br /> with the Florida Energy Code. CO.t?ypE"�� <br /> OWNER/AGENT: BUILDING O FICIAL. <br /> DATE. DATE: - I <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifes as I <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage i <br /> test report in accordance with R402.4.7.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confrming duct leakage to outdoors, <br /> tested in accordance virith Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. � <br /> 8/14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />� � i �� <br /> I <br /> I <br /> I� --- � <br />
The URL can be used to link to this page
Your browser does not support the video tag.