My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18880
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18880
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:34:35 AM
Creation date
7/31/2018 11:34:33 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-18880
Building Department - Name
LENNAR HOMES LLC
Address
3149 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r_ -1 _ ' <br /> � I <br /> , i <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ' <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method � <br /> Project Name. 1941B sf ADS 3ton Builder Name: Lennar Homes 004� i <br /> Street: �lC�� Moulden Hollow Drive Permit Office:C1���f�Ze�phyrhills � <br /> City,State,Zip: ,FL, Pertnit Number <br /> Owner Lennar Homes Jurisdiction:61�1600 <br /> Design Location. FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 ' <br /> b.Frame-Wood,Adjacent - R=11.0 506.78 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4 Number of Bedrooms 4 d.N/A R= ft� <br /> � 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes <br /> a.Under Attic(Vented) R=30.0 1936.00 ft' <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft' <br /> 11 Ducts R ft' <br /> 7 Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft= <br /> SHGC: SHGC=0.31 <br /> b. U-Factor• Dbl, U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency ' <br /> SHGC: SHGC=0.32 a.Central Unit - 34.2 SEER:15.00 i <br /> c. U=Factor• Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Facfor• N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> S. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons � <br /> EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features <br /> b.N/A R= ft� None <br /> c.N/A R- ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 62.94 pASS <br /> Glass/Floor Area: 0.081 Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �.�'TI�:$T,4q�., <br /> this calculation are in compliance with the Florida Energy specifications covered by this � � = �,�"�O . `. <br /> ,�+ ,�4,��t ,__�..� +�+ <br /> Code. calculation indicates compliance � ,,;,_ �_„ ,�. .s+. <br /> /,,� w i t h t he F lori da Energy Co de. �` '`'`:,;`�`w`" � <br /> f�..�rrrorr�"'"� .;::.�,.,�*��;,;ti O <br /> R' �'�;:" �.,,..�... <br /> PREPARED BY: �GtI�� f�Wl�'I� Before construction is completed w ;; � <br /> � _y,,,; :�5�� � <br /> D A T E: t h i s b u i l d i n g w i l l b e i n s p e c t e d f o r L ry _ "�,,.V �s:� <br /> compliance with Section 553.908 *" " `� `Q u ' <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ;,�+,�� ��.s�,. . <br /> with the Florida Energy Code. � U,Zj'�� <br /> OWNER/AGENT. BUILDING OFFICIAL� ' <br /> DATE: DATE. - <br /> - Compliance requires certification by t e air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory-sealed in accordance with R403.2.2.1. -� : <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:24 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.