Laserfiche WebLink
I I <br /> � <br /> ; S i <br /> � <br /> � <br /> ' � � <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ; <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method � , <br /> Project Name. 1 41 B sf ADS 3ton Builder Name: Lennar Homes 0040 � <br /> Street: 3(� � Moulden Hollow Drive Perr„�c o�ice:City of Zephyrhills � <br /> City,State,Zip: ,FL, Permit Number l{�j��Q <br /> Owner Lennar Homes Jurisdiction:611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) ' <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area � <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1454.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R- ft= <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is�this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a.UnderAttic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 1936 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> - 11 Ducts R ft' I <br /> 7 Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor• Dbl,U=0.54 101.00 ft' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ft2 �Z•Cooling systems kBtu/hr Efficiency , <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ftZ � <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N!A ftz a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems ' <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF'0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ft' 15.Credits Pstat <br /> Glass/Floor Area. 0.081 Total Proposed Modified Loads. 62.94 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'t�;s7"`,�q�. . <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��� � ;^y�,,'�0�,;. <br /> Gode. calculation indicates com liance ��i�' °=`��ti`: *�. <br /> with the Florida Energy Code. F+ �rfr,�`'��f.;_=���,��"�`��ti�C1 <br /> /. Q ::s -.�,,.:�,� � , <br /> PREPARED BY. �aVe �����'c Before construction is completed w,� � -+ <br /> t� ,.._r,?c.��S.._ ._._ C7 <br /> DATE. this building will be inspected for try j,,;��E_ s• . <br /> compliance with Section 553.908 .* ��� , ,' � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �� ���. <br /> with the Florida Energy Code. Cd�.WE`� <br /> OWNER/AGENT: BUILDING OFFICI � <br /> DATE: DATE: `'� ; <br /> i. <br /> . - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:24 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />