My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18880
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18880
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:34:35 AM
Creation date
7/31/2018 11:34:33 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-18880
Building Department - Name
LENNAR HOMES LLC
Address
3149 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� i <br /> � <br /> � <br /> � 4 <br /> ., _ i <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ; <br /> Florida Department of Business and Professional Regulation - Residential Performance Method ' <br /> � <br /> Project Name. 1941 B sf ADS 3ton Builder Name: Lennar Homes 0040 , <br /> street: Moulden Hollow Drive Permit oftice:City of Zephyrhills � <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• Lennar Homes Jurisdiction:611600 <br /> Design Location: FL,Tampa County�• Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft:) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1454.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft' <br /> 3. Number of units,if multiple family 1 c.N/A R- ft� � <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 <br /> . a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ft=) 1936 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor• Dbl,U=0.54 101.00 ftz <br /> SHGC: SHGC=0.31 <br /> _b. U-Factor Dbl,U=0.56 33.33 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 342 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ft= <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 � <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> 8. FloorTypes (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features <br /> b.N/A R= ft= None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 <br /> Total Proposed Modified Loads: 62.94 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ����:��'.q� <br /> Q .. r + . <br /> this calculation are in compliance with the Florida Energy specifications covered by this �,,�.�, ��0�, <br /> ���` . <br /> Code. calculation indicates compliance � a„_ '__�:,,�. �+s+ ' <br /> IFIt{/i._i ` c-�.�x�1���* l"` <br /> /. with the Florida Energy Code. �� �%;..,,:-`����,,,, O , � <br /> PREPARED BY. �aVe �����'c Before construction is completed u�� � � � i <br /> DATE. this buildin will be ins ected for � '����" � <br /> 9 P t9 . �,,��:` ..._.. � . I <br /> compliance with Section 553.908 � ��° • <br /> .`:� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .� ,_', �.� <br /> with the Florida Energy Code. �O,�j;y�r�'T'�� <br /> OWNER/AGENT: BUILDING OFFICIAL. / <br /> DATE: DATE. - ' � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ' <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:24 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />�_ <br />