Laserfiche WebLink
. : <br /> � <br /> Manual S Compliance Report Job: 3127AB sf ADS <br /> Date: 8/1012017 <br /> upper floor By: Dave Aldrich <br /> � Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> � � ' • • <br /> For: Lennar Homes <br /> • • . • • <br /> Design Conditions <br /> Outdoor design DB. 91.3°F Sensible gain: 19456 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 3101 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB. 75.0°F Total gain: 22557 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br />' Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model. 14HPX-024-230-21+CBA27UHE-024-230*++TDR <br /> I Actual airflow: 800 cfm <br /> Sensible capacity� 21420 Btuh 110% of load <br /> Latent capacity: 3780 Btuh 122% of load <br /> Total capacity: 25200 Btuh 112% of load SHR: 85% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 15756 Btuh Entering coil DB. 69.6°F <br /> Indoor design DB� 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 138% of load Capacity balance: 23 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 4.7 kW 102% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. <br /> .� wri htsoft� 2017-Aug-1013:20:33 <br /> 1, 9 Right-Suke�Universal 2017 17.0.23 RSU05714 Page 2 <br /> �'� .BA27UHE AH's\3127AB sf ADS template 2-2tons.rup Calc=MJS Front Door faces: S <br />