My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18889
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18889
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:45:39 AM
Creation date
7/31/2018 11:45:00 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18889
Building Department - Name
LENNAR HOMES LLC
Address
36006 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> :� <br /> � FORIVI R405-2014 <br /> � FLI�RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> -r�•, <br /> Project Name: 1941A sf ADS Buildefi�lame: Lennar Homes <br /> street: 36006 Stable Wilk Avenue � Perrri�t office: Ci �jf�phyrhills <br /> City,State,Zip. ,FL, Permit Number ri�C7 <br /> Owner� Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County�� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br />� a.Concrete Block-Int Insul,Exterior R=4 1 1454.60 ftz <br /> 2. Single family or multiple family Single-family b.Frame-Wood,Ad'acent �, <br /> 1 R=11.0 506.78 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4 Number of Bedrooms 4 d.N/A R- ft= <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ftz <br /> 7 Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft� • <br /> SHGC� SHGC=0.31 <br /> b. U-Factor• Dbl,U=0.56 33.33 ft� 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.32 a.Central Unit 34.2 SEER:15.00 , <br /> c. U-Factor Dbl,U=0.56 23.00 ft= <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U=Factor• N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC� 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area . EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features <br /> b N/A R= ftZ None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/FloorArea: 0.081 Total Proposed Modified Loads: 61.81 pASS <br /> Total Baseline Loads. 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0�'���T.q�,�.� . <br /> this calculation are in compliance with the Florida Energy specifications covered by this �4. ; � ''a.�.� t7,��;, <br /> Code. calculation indicates compliance v�'��;,r,.�`�, �,�r._^`;.•����,'�+Y„ �' <br /> �ave �Gol�cG� with the Florida Ener Code. �+ 1urrr� ''��.•.,�����'.�`'+�,ti O <br /> 9Y . ..�� ��,,::+�t.. <br /> PREPARED BY. Before construction is completed c i •;� '�" '° � <br /> DATE: this building will be inspected for �: �l�i°" ;� <br /> ki� <br /> compliance with Section 553.908 * ��' � �, - <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ;�,i,� , " ��� <br /> with the Florida Energy Code. a1]{�y�'i''i�' <br /> CHECKED AUG 0 8 <br /> OWNER/AGENT. �UILDING OFFICIAL. <br /> DATE: DATE. � <br /> - Compliance requires certification y the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> I - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.