My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18889
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18889
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:45:39 AM
Creation date
7/31/2018 11:45:00 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18889
Building Department - Name
LENNAR HOMES LLC
Address
36006 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C � <br /> • FORM R405-2014 <br /> � FL�RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941A sf ADS Builder Name: Lennar Homes <br /> street: 36006 Stable Wilk Avenue Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• Lennar Homes .lurisdiction: 611600 <br /> Design Location: FL,Tampa County�� Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing , New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br />� 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1454.60 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4 Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a.UnderAttic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 1936 b.N/A R= ft� <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11.Ducts R ftz <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor• � Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.32 , a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor• Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC� <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC� 0.308 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation ,R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0 081 Total Proposed Modified Loads 61.81 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'����T,��. . <br /> this calculation are in compliance with the Florida Energy specifications covered by this �1.� � '" =- ;�Q�. `. <br /> Code. calculation indicates compliance �. �:,,;'' , �:s;.-��,.��1��. <br /> � � :,-:•r�.•�4.� <br /> �a�e �/,��G/I with the Florida Energy Code. �rrra ' � ,x O. _ <br /> PREPARED BY� p �, "' �"'���� <br /> W� �� Before construction is com leted w�i � <br /> DATE. this building will be inspected for t�,g �����: ;'� : <br /> � ;.. <br /> compliance with Section 553.908 ,; ��:`° : _„ <br /> Florida Statutes. ;� . • :� X �: <br /> I hereby certify that this building,as designed, is in compliance �C � . �g. <br /> with the Florida Energy Code. dD yyE`;� <br /> OWNER/AGENT. BUILDING O FI . <br /> DATE: DATE. ' r <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1..1 and an envelope leakage ' <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.