My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18889
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18889
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:45:39 AM
Creation date
7/31/2018 11:45:00 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18889
Building Department - Name
LENNAR HOMES LLC
Address
36006 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> ' FORIVI R405-2014 <br /> ' FLORIDA ENERGY EFFICIENCY CODE .FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941A sf ADS Builder Name: Lennar Homes <br /> i screet: 36006 Stable Wilk Avenue Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, , Permit Number <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br />, 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? Yes �0.Ceiling Types (1936.0 sqft.) Insulation Area x <br /> a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0. c.N/A R= ftZ <br /> 11 Ducts R ftz <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 • <br /> a. U-Factor Dbl,U=0.54 101.00 ftz <br /> SHGC� SHGC=0.31 <br /> b. U-Factor• Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features <br />, b.N/A R= ft2 None <br /> c.N/A R= ftZ 15 Credits Pstat <br /> Glass/FloorArea: 0.081 Total Froposed Modified Loads 61.81 pASS <br /> Total Baseline Loads: 62.6� <br /> I hereby ce�tify that the plans and specifications covered by Review of the plans and ��'T�E S�"'.q?.�. -. <br /> this calculation are in compliance with the Florida Energy specifications covered by this 4 , �-.;•, 0,�,. .. <br /> Code. calculation indicates compliance ,r,���;,,�'` , b:;,�`�a���� ,��„ ` <br /> �ave �/,��G/- with the Florida Energy Code. �+ jrrrr.���'��-, .;.;:��y�.s�'-�,,,,, O <br /> 'PREPARED BY w< « Before construction is completed w`�i � " _ �+ <br /> r� �. .+��,. .._. � <br /> DATE: this building will be inspected for � l,rG;,. :'� <br /> compliance with Section 553.908 * '� ° � ,,. .� <br /> � I hereby certify that this building,as designed, is in compliance Florida Statutes. �,i, '_,. ����: <br /> with the Florida Energy Code. ��I?yWE`� � <br /> OWNER/AGENT: BUILDING FIC L. <br /> DATE. � DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. ' <br />� - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.