Laserfiche WebLink
5 � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 3711 B sf ADS Builder Name: LENNAR HOMES <br /> street: 6468 Paden Wheel Street Permit o�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> OWner. LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1738.70 ft� <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1487.10 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ftz <br /> 4. Number of Bedrooms 4 d.N/A R= �: <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2134.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2002.00 ft <br /> 6. Conditioned floor area above grade(ft� 3720 b.Knee Wall(Vented) R=30.0 132.00 ft2 - <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(368.4 sqft.) Description Area a.Sup: 1st Floor,Ret:1st Floor,AH:1st Floor 6 343.6 <br /> a. U-Factor: Dbl,U=0.54 138.35 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 400.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 123.36 ft� 12-Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 106.67 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 3.101 ft. <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems <br /> 8. Floor Types (3720.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Floor Over Other Space R=0.0 1725.00 ftZ b. Conservation features <br /> b.Slab-On-Grade Edge Insulation R=0.0 1718.00 ftZ None <br /> c.other(see details) R= 277 00 ftz 15.Credits Pstat <br /> Glass/Floor Area. 0.099 Total Proposed Modified Loads: 100.83 pASS <br /> Total Baseline Loads: 101.64 <br /> I hereby certify that the plans and specifications covered by Review of the plans and : ��'L�ST�gfi�, ,_ <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ,��, '�T��; p�. <br /> Code. calculation indicates compliance �, �,,, '' :_�;�:��.`.� , <br /> /I with the Florida Energy Code. F* rrrri.�"?�•:;=:�°.;:��.'��ti, � <br /> PREPARED BY: �aVe �����'c Before construction is completed r� `�" <br /> DATE. this building will be inspected for � � . �� <br /> , <br /> compliance with Section 553.908 ' * -� � .= �.�. ` <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. . � <br /> Y fY 9� 9 P '�?' " �s- <br /> with the Florida Energy Code. C�Li�yy�.`I�'t', <br /> OWNER/AGENT: BUILDING O FICIAL: <br /> DATE: DATE: � � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.070 Qn for whole house. <br /> 8/11/2017 10:45 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />