Laserfiche WebLink
� ' <br /> FORM R405-2014 . <br /> FLORIDA ENERGY EFFtCIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Perfarmance Method <br /> 1 <br /> Project Name: 3711 B sf ADS Buitder Name: LENNAR HOMES <br /> street: 6468 Paden Wheel Street �ermit at�ce: City of Zephyrhills <br /> Gity,State,Zip: ,FL, Permit Number• <br /> Owner. LENNAR HOMES Jurisdiction: 61 I600 <br /> � Design Location: FL.,Tampa County Pasco(Florida Glimate Zone 2) <br /> 1. New construction or existing New(From Plans) 9, Wall Types(3424.9 sqft.) Insulation Area <br /> 2. Single fami(y or multipta family Single-family a.Frame-Wood,E�ckerior R=41 A 9738.70 ft2 <br /> b.Cancrete Block-Int Insul,Exterior R=4.1 1487.10 fkZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.Q 199.11 ftx <br /> 4. Nurnber of Bedrooms 4 d.NtA R= ftx <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2134.Q sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 2002.00 ft <br /> 6. Gonditioned fioar area above grade(ft2) 372D b.Knee Wall(Vented} R=30.4 132.Od ftz <br /> Conditioned floor area below grade(ft�) 0 c.N/A R= ft2 <br /> 11_Ducts R ftZ <br /> 7. tNindows{368.4 sqR.} Qescripfion Area a.Sup:1st Floor,Ret:ist Floor,AH:1s#Ftoor 6 343.6 <br /> a. U-Factor• Dbl,U=0.54 138.35 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 400.4 <br /> SHGG: StiGC=0.31 <br /> b. U-Factor Db(,U=0.56 123.36 ft2 �2•Cooiing systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Centta!Unit 25.2 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 106.67 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor. N/A ft2 a.Etectric Heat Pump 27.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 3.101 ft. <br /> Area Weighfed Average SHGC: 0.303 14.Hot water systems <br /> 8. Floor Types (3720.0 sqft.) Insulation Area a.Electric Cap:40 ga(lons <br /> EF:0.950 <br /> a.Floor Over Other Space R=0.0 1725.04 ft2 b. Conservation features <br /> b.Slab-On-Grade Edge Insulation R=0.0 1718.00 ft2 None � <br /> c.othe�(see details) R= 277.00 ft2 �5.Credits Pstat <br /> Glass/Floor Area: 0,099 ratal Praposed Modified Loads: 100.83 � A �� <br /> Total Baseline Loads: 101.64 '�i <br /> 1 hereby certify that the plans and specifications covered by Review of fhe plans and �'fi"�:�T.�j�: <br /> 0 �� �r :a,,� <br /> this calculation are in compliance with the Florida Energy specifications cavered by this �e� ,�:. ^.4��"�0�: <br /> Code. calcufation indicates campliance �,�'�'tf,,''' `== �.�� -�s+ .. <br /> ,•t ia t � <br /> /I with the Florida Energy Code. t�• rr,�ri�`:�i%-;;r;��a.�i- n"G3 � <br /> PREPARED BY: �QVe �����'` Before constructian is completed c� ° `"`�� �`��•" <br /> DATE: this building will bainspected for � �'� �` � ., �= _� <br /> compliance with Section 553.908 „ . " • �'� � :� .��,.' � <br /> I hereb certi that this buildin as desi ned,is in com liance Florida Statutes. � �:� � <br /> Y fY 9, 9 P = "1�_ :�. . . <br /> with the Ftorida Energy Coda. � ti`y�`t'�� - <br /> OWNER7AGENT: BUILDlNG OFFIClA�: <br /> DATE. DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure quaSifies as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance cequires an Air Rarrier and tnsulatian tnspection Ghecklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accardance with R402.4.1.2. <br /> - Compliance with a propased duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 8�3 af RESNET Standards,is nat greater than 0.470 Qn for whole house. <br /> 8/11/2017 10:A5 AM EnergyGaugeb USA-FlaRes2014 Section R405.4.1 Compliant Soffware Page 1 of 5 <br />