Laserfiche WebLink
( ( ' <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2268A sf ADS Build�r Name: LENNAR HOMES O402 <br /> street: 6477 Paden Wheel Street Perr„�c o�r.�: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner. LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 364.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d•N�'4 R= ftZ <br /> 10.Ceiling Types (2267.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267:00 ftZ <br /> 6. Conditioned floor area above grade(ftz) 2267 b.N/A R= ft2 <br /> z <br /> Conditioned floor area below grade(ft2) 0 c. A R= ft <br /> 11.Ducts R ft2 <br /> 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453 <br /> a. U-Factor Dbl,U=0.54 143.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.58 96.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 38.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.206 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2267.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 75.57 pASS <br /> Glass/Floor Area: 0.122 Total Baseline Loads: 76.12 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'fN�STA�,� •,. <br /> O '_'-r��> > <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' y- _� O <br /> �i,; :=p:. ..�t�. '' <br /> Code. calculation indicates compliance . .;�'�"�;,� � _ �.•� ,�s+. . <br /> �ave ���G� with the Florida Energy Code. ��+ ��rrf.�'%:":;•_::�':;;•�'��ti,�O ` <br /> PREPARED BY' Before construction is completed r i '"' ;� � <br /> DATE: this building will be inspected for � -`1�1��---- - �° .� <br /> �u I .� <br /> compliance with Section 553.908 *. - �� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .� - = ` ,S <br /> with the Florida Energy Code. G'OZj' ����. <br /> � W�. <br /> OWNER/AGENT: BUILDING OFFICIAL� <br /> DATE. DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house. <br /> 8/11/2017 12:29 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />