My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18982
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18982
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 2:23:00 PM
Creation date
7/31/2018 2:22:59 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18982
Building Department - Name
LENNAR HOMES LLC
Address
6477 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( 1 <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 2268A sf ADS Builder Name: LENNAR HOMES O402 <br /> street: 6477 Paden Wheel Street Permit�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County�• Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 364.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 10.Ceiling Types (2267.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267.00 ftZ <br /> 6. Conditioned floor area above grade(ftZ) 2267 b.N/A R= ftZ <br /> z <br /> Conditioned floor area below grade(ft2) 0 11 Ducts R R ffz <br /> 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453 <br /> a. U-Factor: Dbl,U=0.54 143.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor• Dbl, U=0.58 96.00 ft2 �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 38.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.206 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2267.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 75.57 pASS <br /> Glass/Floor Area: 0.122 Total Baseline Loads: 76.12 <br /> I hereby certify that the plans and specifications covered by Review of the plans and . �.�Zk1E,ST�T� .., <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��y ' "_ �. p <br /> Code. calculation indicates compliance � �'��;,��s ,`=?`�4�.�.K+. . <br /> ,{ with the Florida Energy Code. ti�+urr�.'?. -.;;:=',�.•,•���s �O' <br /> PREPARED BY: _ �aVe tf���� Before construction is completed i� •, " "``�`� �� <br /> DATE. this buildin will be ins ected for �' � ��"- �-- " � Q <br /> 9 P � ��;;�(� �. . <br /> compliance with Section 553.908 *, .�.�..- ,. ..* <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� , - ;�_. <br /> with the Florida Energy Code. G'OZy��� ' <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE. DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enc osure qualifies as <br /> certifed factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 8/11/2017 12:29 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.