My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19001
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2018 11:50:09 AM
Creation date
8/13/2018 11:50:07 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-19001
Building Department - Name
LENNAR HOMES LLC
Address
6620 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' } . <br /> FORM-R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> 0307 <br /> Project Name: 2268AB sf ADS Builder Name: LENNAR HOMES <br /> street: 6620 Paden Wheel Street Permit o�ice: pasco <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 364.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= �{_ <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2267.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2267.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2267 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0, c.N/A R= ftz <br /> 11.Ducts R ft2 <br /> 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453 <br /> a. U-Factor Dbl,U=0.54 143.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 96.00 ftZ 12.Cooling systems kBtulhr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 38.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.206 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> 8. FloorTypes (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2267 00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.122 Total Proposed Modified Loads: 75.57 pASS <br /> Total Baseline Loads: 76.12 <br /> � - <br /> I hereby certify that the plans and specifications covered by Review of the plans and �Tk�:ST�q7, .. <br /> this calculation are in compliance with the Florida Energy specifications covered by this � `�v��: � _.,�;;�0�_�., <br /> Code. calculation indicates compliance • �'��,;,�''; `==a:����:� . <br /> �aVe ���G� with the Florida Energy Code. ' d: �r�rri�+�1��,�:::r�".�;;���'���ti O . <br /> .,��� A . <br /> PREPARED BY: Before construction is completed � •, ' '� � <br /> DATE: this building will be inspected for � �7���- `. :� <br /> compliance with Section 553.908 ' *� �. :- -,* <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. �� <br /> Y fY 9� 9 P � ;'�. _ . . . <br /> with the Florida Energy Code. C�D�y�t�'�� - <br /> OWNER/AGENT� BUILDING OFFICIAL: ��CC� - <br /> DATE. DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house. <br /> 9/25/2017 9:55 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.