Laserfiche WebLink
i � � • <br /> FORM�R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br />� Project Name: 2268AB sf ADS Builder Name: LENNAR HOMES 0307 <br /> street: 6620 Paden Wheel Street Permit o�ice: pasco <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner. LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate 2one 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz � <br /> b.Frame-Wood,Adjacent R=11.0 364 00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 I <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2267.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 2267.00 ft <br />, 6. Conditioned floor area above grade(ftZ) 2267 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453 <br /> a. U-Factor: Dbl,U=0.54 143.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.58 96.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 38.00 ftz �i <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ft� a.Electric Heat Pump 32.8 HSPF:8.50 <br />, SHGC: <br /> Area Weighted Average Overhang Depth: 4.206 ft. <br /> Area Weighted Average SHGC: 0.309 14 Hot water systems <br /> 8. FloorTypes (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 75.57 pASS <br /> Glass/Floor Area: 0.122 <br /> Total Baseline Loads: 76.12 <br /> I hereby certify that the plans and specifications covered by Review of the plans and : ��;T�:$T�j�.� -.. I <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ' ��' , , � = 0�,, <br /> Code. calculation indicates compliance �"�+'�;,,��'' ,�.�::�,�����.,*s+r, <br /> �ave ���G/, with the Florida Energy Code. �+ »rr'r �:'%%-.,,��",�';����titi O <br /> PREPARED BY �� Before construction is completed r� � �, '� "-`�""'" � <br /> �' - � �(� ��__ . �- C <br /> DATE: this building will be inspected for � �I',;�� �. <br /> compliance with Section 553.908 ' *, -� '�. =.� <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � <br /> Y fY 9� 9 P , � � <br /> with the Florida Energy Code. -_ C�D�yy�'1'��- <br /> OWNER/AGENT: BUILDING FFICIAL: <br /> DATE: DATE: - - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accardance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house. <br /> 9/25/2017 9:55 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />