Laserfiche WebLink
r ; <br /> Manual S Compliance Report �ob: 2889A1 sf ADS <br /> Date: 1011312017 <br /> lower floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' � - • � <br /> For: Lennar Homes <br /> • • • • • <br /> Design Conditions <br /> Outdoor design DB: 92.4°F Sensible gain: 19276 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.4°F Latent gain: 2905 Btuh Entering coil WB. 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 22181 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model. 14HPX-024230-21+CBA27UHE-024230'`++TDR <br /> Actual airflow� 800 cfm <br /> Sensible capacity: 21420 Btuh 111% of load <br /> Latent capacity: 3780 Btuh 130°/a of load <br /> Total capacity: 25200 Btuh 114% of load SHR: 85% <br /> � � <br /> � • � <br /> Design Conditions , <br /> Outdoor design DB: 30.8°F Heat loss. 23100 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB. 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model 14HPX-024230-21+CBA27UHE-024-230'`++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 94% of load Capacity balance: 33 °F <br /> Supplemental heat required: 1300 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 6.5 kW 96% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. <br /> ,� wri htsoft° 2017-Oct-13 07�10:53 <br /> 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> �� ...BA27UHE AH's\2889A sf template ADS 1.5-2ton.rup Calc=MJ8 Front Door faces:SE <br />