My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19065
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19065
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2018 2:15:16 PM
Creation date
8/16/2018 2:15:14 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19065
Building Department - Name
LENNAR HOMES LLC
Address
3137 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- . . � <br /> Manual S Com liance Re ort Job: 2889A1 sf ADS <br /> p p Date: 1 011 312 01 7 <br /> �� upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - • � <br /> For: Lennar Homes <br /> � • • • � <br /> Design Conditions <br /> Outdoor design DB: 92.4°F Sensible gain: 12739 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.4°F Latent gain: 2049 Btuh Entering coil WB 62.9°F <br /> Indoor design DB. 75.0°F Total gain: 14788 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR <br /> Actual airflow: 600 cfm <br /> Sensible capacity� 15300 Btuh 120% of load <br /> Latent capacity: 2700 Btuh 132% of load <br /> Total capacity: 18000 Btuh 122% of load SHR: 85% <br /> . • • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss 10946 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230"++TDR <br /> Actual airflow: 600 cfm <br /> Output capacity: 17500 Btuh 160% of load Capacity balance: 20 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip � <br /> Manufacturer: Model: <br /> Actual airflow� 600 cfm <br /> Output capacity: 3.1 kW 98% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S <br /> ,,.� wri htsoft' 2017-Oct-13 07�10:53 <br /> 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2 <br /> �� ...BA27UHE AH's\2889A sf template ADS 1.5-2ton.rup Calc=MJ8 Front Door faces:SE <br />
The URL can be used to link to this page
Your browser does not support the video tag.