Laserfiche WebLink
Buildin Anal S�S Job: 1941A sf ADS <br /> g y Date: 9H312017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - e � <br /> For: Lennar Homes <br /> � - • • � • <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft Design TD (°F) 39 16 <br /> Latitude: 28°N Relative humidity(%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 <br /> Dry bulb(°F) 31 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb(°F) - 77 Construction quality Semi-tight <br /> Wind speed(mph) 15.0 7.5 Fireplaces 0 <br /> • <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 5.6 7030 24.6 �«S <br /> Gl2zlllg 30.2 4739 16.6 wa�� <br /> Doo�s 23.5 466 1.6 n�i�tration <br /> Ceilings 1.3 2429 8.5 <br /> Floors 3.5 6726 23.5 <br /> Infiltration 2.8 3996 14.0 <br /> D ucts 3223 11.3 <br /> Piping 0 0 Glazing <br /> Humidification 0 0 Floors <br /> Other <br /> Ventilation � � Ceilings <br /> . Adjustments 0 <br /> Total 28608 100.0 <br /> • • • <br /> Component Btuh/ft2 Btuh % of load <br /> Walls 2.8 3497 13.4 Walls <br /> Glazing 56.9 8927 34.2 Intemal Gains <br /> Doors 18.4 365 1.4 <br /> Ceilings 1.7 3358 12.9 <br /> Floors 0 0 0 ( <br /> Infiltration 0.6 880 3.4 <br /> Ducts 3621 13.9 oucts <br /> Ventilation 0 0 Glazing � <br /> Internal gains 5455 20.9 <br /> Blower 0 0 Infiltration <br /> Adjustments 0 <br /> Total 26103 100.0 Other Ceilings <br /> Latent Cooling Load=4171 Btuh <br /> Overall U-value= 0.103 Btuh/ft2-°F <br /> Data entries checked. <br /> � -�1- wrightsoft� 2017-Sep-13 10:21:30 <br /> �� Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...th CBA27UHE AH's\1941A sf ADS template 3ton.rup Calc=MJS Frant Door faces:NW <br />