Laserfiche WebLink
Pro ect Summa Job: 1941A Sf A�s <br /> .� . � Date: 9l13l2017 <br /> Enfire House gv: aa�e <br /> Bayonet Plumbing Heating and Air ' <br /> ' • - • s <br /> For: Lennar Homes <br /> Notes: 2017 <br /> � ^ i i i <br /> Weather: Tampa Internationa!AP, F�, US <br /> Winter Design Conciitions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> lnside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 54 °!o <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensibie Caoling Equipment Load Sizing <br /> Structure 25385 Btuh Structure 2248'S Btuh <br /> Ducts 3223 Btuh Ducts 3629 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm} 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipmer►t load 28608 Stuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> tnf(tr�tion Equipmen#sensible load 26103 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces Q Structure 3525 Btuh <br /> Ducts 646 Btuh <br /> Central vent{4 cfm) 0 Stuh <br /> Heating Cooling (none) <br /> Area(ft2 '1936 1936 Equipmen#latent load 417'1 Btuh <br /> Valume�ft'} 16360 16360 <br /> Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 30273 Btuh <br /> Equiv.AVF(cfm} 93 49 Req. total capacity at 0.85 SFiR 2.6 tan <br /> Heat'rng Equipment Surnmary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Modei 14NPX-036-230-21 Cond 14HPX-036-230-21 <br /> AHR) ref 10258589 Coil CBA27UHE-036-230"`++TDR <br /> AHRI ref 10258589 <br /> Efficiency 8.5 NSPF Efficiency 12.5 EER, 95 SEER <br /> Heating input Sensible cooling 29580 Btuh <br /> Heating output 32800 Btuh @ 47°F Latsnt cooling 5220 Btuh <br /> Temperature rise 25 °F Total cooling 34800 Btuh <br /> Actual air flaw 1200 cfm Actua(air flow 1200 cfm <br /> Air flow fac#ar 0.042 cfmlBttsh Air flaw factor 0.046 cfmlBtuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space fhermostaf Load sensible heat ratia 0.86 <br /> Capacity balance paint=29°F <br /> Backup: n!a n!a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA ta meet all requirements of Manua!J 8th Ed. <br /> �r, "�" wrightsoitm Right-Suite�Universal 2017 17.0.23 RSU05714 2017Sep-13 1�:2130 <br /> .�R..C+P. Page 1 <br /> ...th CHA27UHE AH's\i941A sf ADS temptate 3ton.rup Catc=MJB Front Roor faces:NW <br />