Laserfiche WebLink
- , , . . <br /> Manual S Compliance Report Job: 1941A sf ADS <br /> Date: 9/1312017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - • � <br /> For: Lennar Homes <br /> • • • • . <br /> Design Conditions <br /> Outdoor design DB 91.3°F Sensible gain: 26103 Btuh Entering coil DB: 75.6°F <br /> 0 0 <br /> Outdoor desi n WB: 77.3 F La en ain: 41 1 B <br /> g t t g 7 tuh Entermg coil WB. 62.8 F <br /> Indoor design DB. 75.0°F Total gain: 30273 Btuh <br /> Indoor RH: 50% Estimated airflow� 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29070 Btuh 111% of load <br /> Latent capacity: 5130 Btuh 123% of load <br /> Total capacity' 34200 Btuh 113% of load SHR: 85% <br /> . • • <br /> Design Conditions <br /> Outdoor design DB� 30.8°F Heat loss• 28608 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR <br /> - Actual airflow: 1200 cfm <br /> Output capacity: 32800 Btuh 115% of load Capacity balance: 29 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> i Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 �F <br /> Meets are all requirements of ACCA Manual S. <br /> ,� wri htsoft� 2017-Sep-1310:21:30 <br /> 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> �� ...th CBA27UHE AH's\1941A sf ADS template 3ton.rup Calc=MJ8 Front Door faces:NW <br />