Laserfiche WebLink
� . . . . <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1551 B sf ADS Builder Name: Lennar Homes <br /> street: 3186 Moulden Hollow Drive Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: �FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 316.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1555.00 ft' <br /> 6. Conditioned floor area above grade(ftz) 1555 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ftZ <br /> 7 Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 I <br /> a. U-Factor Dbl,U=0.54 55.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ftz 12-Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 16.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.319 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (1555.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> z <br /> c. A R= ft 15.Credits Pstat � <br /> Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.84 p A C C I <br /> Total Baseline Loads: 50.87 r/`'1�7�7 <br /> I hereby certify that the plans and specifications covered by Review of the plans and Tk�.E;S� . <br /> this calculation are in compliance with the Florida Energy ' specifications covered by this -���� _ �rQO , <br /> Code. calculation indicates compliance '��±�,,,�''� `'-���;��K+ . <br /> �" with the Florida Energy Code. �+ �irrr`,�%�.�;:::�.,;.�i�`•`ti,'r0 , <br /> PREPARED BY: �2G�'1/� f��j'I�YC Before construction is completed ' ''y �"°`-"'" ��� <br /> DATE. this buildin will be ins ected for ~ <br /> 9 P C7 �`_1�'�j �: ;� . <br /> compliance with Section 553.908 ' * -�~'� ' :_ _� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .� , , �,� <br /> with the Florida Energy Code. G'Otj yyj,;:�� _ <br /> OWNER/AGENT: BUILDINC�OFFICIAL: <br /> DATE. DATE: �l��L��� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 Qn for whole house. <br /> 9/13/2017 12:05 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />