My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19068
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19068
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2018 2:19:18 PM
Creation date
8/16/2018 2:19:16 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19068
Building Department - Name
LENNAR HOMES LLC
Address
3186 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> , , , . • • . <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1551 B sf ADS Builder Name: Lennar Homes <br /> street: 3186 Moulden Hollow Drive Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number� <br /> Owner. Lennar Homes Jurisdiction: 611600 - <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 316.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= �_ <br /> 4. Number of Bedrooms 3 d.N/A R= �: <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1555.00 ft <br /> 6. Conditioned floor area above grade(ft� 1555 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 <br /> a. U-Factor� Dbl,U=0.54 55.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 16.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.319 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1555.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= �Z 15.Credits Pstat <br /> Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.84 pASS � <br /> Total Baseline Loads: 50.87 <br /> I hereby certify that the plans and specifications covered by Review of the plans and :a�'S�:S�':q�,� --._ <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��S' ,, ' __-�_� O . <br /> Code. calculation indicates compliance ���i;,T;'�, `_ '�:``:�.�e+ <br /> �" with the Florida Ener Code. �+ iir,i, `�, •,;:::�:•;:+.�` � ` <br /> PREPARED BY: �7G�VG f���'(GYG 9Y � ' ;:�;-w;'` 51 p <br /> Before construction is completed ` � <br /> DATE: this buildin will be ins ected for � �`��' , ~ ',i` O <br /> 9 P t� � -��ll� �. ; <br /> compliance with Section 553.908 �:, : .-,�. . I <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. -�C ` ��.t I <br /> with the Florida Energy Code. �D'y�i�'C¢ , <br /> OWNER/AGENT: BUILDIN OFFICIAL: <br /> DATE. DATE: �- � - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house. <br /> 9/13/2017 12:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />