. ! <br />�� i <br /> _ Plan Review C103.2 Exterior Lighting Pians,specifications,and/or calculations provide � � � <br /> all information with which compiiance can be <br /> determined for the exterior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. � <br /> Information provided should include exterior ' <br /> lighting power calculations,wattage of bulbs and � <br /> ballasts,transformers and control devices. <br /> Wattage C405.6.2 Exterior Lighting Exterior lighting power is consistent with what is � � � <br /> shown on the appraved lighting plans, <br /> demonstrating proposed watts are less than or <br /> equal to allowed watts. � <br /> Plan Review C103.2 Interior Lighting Plans,specifications,and/or calculations provide � � � <br /> all information with which compliance can be <br /> determined for the interior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided should include interior ' <br /> lighting power calculations,wattage of bulbs and � <br /> ballasts,transformers and control devices. <br /> HVAC C403.2.5.1 Mechanical Demand control ventilation provided for spaces � � � <br /> >500 ft2 and>25 people/1000 ft2 occupant <br /> density and served by systems with air side <br /> economizer,auto modulating outside air damper ' <br /> control,or design airflow>3,000 cfm. � <br /> HVAC C403.2.4.3 Mechanical Each zone equipped with setback controls using � � � <br /> automatic time clock or programmable control <br /> system. <br /> Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide � � � <br /> all information with which compliance can be <br /> determined for the mechanical systems and - <br /> equipment and document where exceptions to the i <br /> standard are claimed. Load calculations per i .� <br /> acceptable engineering standards and � <br /> handbooks. <br /> Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide � � � ; <br /> all information with which compliance can be <br /> � determined for the service water heating systems � <br /> and equipment and document where exceptions <br /> to the standard are claimed. Hot water system <br /> sized per manufacturer's sizing guide. <br /> SYSTEM_SPECIFIC C403.4.5 Mechanical Zone controls can limit simultaneous heating and � � � , <br /> cooling and sequence heating and cooling to each , <br /> zone. � <br /> SYSTEM_SPECIFIC C403.4.3.1 Mechanical Three-pipe hydronic systems using a common � � � <br /> retum for hot and chilled water are not used. � <br /> SYSTEM_SPECIFIC C403.4.3.2 Mechanical Two-pipe hydronic systems using a common � � � i <br /> distribution system have controls to allow a <br /> deadband>=15°F,allow operation in one mode � � <br /> for at least 4 hrs before changeover,and have , , <br /> � rest controls to Iimit heating and cooling supply <br /> temperature to<=30°F <br /> SYSTEM_SPECIFIC C403.4.3.3.1 Mechanical Hydronic heat pump systems connected to a � � � i <br /> common water loop meet heat rejection and heat <br /> addition requirements. <br /> SYSTEM_SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have � � � <br /> - means to balance and have pressure test I <br /> connections. <br /> SYSTEM_SPECIFIC C403.4.2 Mechanical VAV fan motors>=7 5 hp to be driven by variable � � � <br /> speed drive,have a vane-axial fan with variable <br /> pitch blades,or have controls to limit fan motor <br /> demand. <br /> SYSTEM_SPECIFIC C403.4.2.1 Mechanical VAV fans have static pressure sensors positioned � � � <br /> so setpoint<=1/3 total design pressure. i <br /> SYSTEM SPECIFIC C403.4.2.2 Mechanical Reset static pressure setpoint for DDC controlled ; <br /> VAV boxes reporting to central controller based on '• <br /> the zones requiring the most pressure. <br /> SYSTEM_SPECIFIC C403.4.5.4 Mechanical Multiple zone HVAC systems have supply air � � � <br /> temperature reset controls. <br /> SYSTEM_SPECIFIC C403.4.3.4 Mechanical Hydronic systems greater than 300,000 Btu/h � � � <br /> designed for variable fluid flow <br /> EnergyGauge Summit0 Fla/Com-2014.TAM 2014-1.0 Compliant Software.Effective Date:June 30,2015 <br /> Florida Building Code, Fifth Edition(2014)-Energy Conservation IECC 2012-Total Building Performance Compliance Option <br /> 1/11/2017 Page 9 of 13 , <br /> ; __' <br />