My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19005
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 1:58:54 PM
Creation date
9/17/2018 1:58:46 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19005
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6780 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job: Ryman 6 Plex <br /> .�.. ��.��h.��p.�a Project Summary Date: SepO6,zo,7 <br /> Unit 4 By: DJM <br /> ' • - . • � <br /> For: Ryman 6 Plex <br /> Dade City,FL <br /> Notes: <br /> D - • • e <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 27 °F Design TD 16 °F <br /> Daily range � <br /> Relative humidity 50 % <br /> Moisture difference 54 gdlb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 6111 Btuh Structure 8327 Btuh <br /> Ducts 2331 Btuh Ducts 3390 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 8442 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 0.96 <br /> Infiltration Equipment sensible load 11295 Btuh <br /> Method simp�itied Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 1846 Btuh <br /> Ducts 814 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none} ' <br /> Area(ft2) 1090 1090 Equipment latent load 2660 Btuh <br /> Uolume(fN) 9693 9693 <br /> Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh <br /> Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton <br /> Heating Equipenent Suer�enary Cooling Equiprraent Summary <br /> Make Make Carrier <br /> Trade 5 KW Trade CARRIER AIR CONDITIONING <br /> PVlodel Cond 24ACB318ABN32 <br /> AHRI ref Coil FB4CNP018L <br /> AHRI ref 9859025 <br /> Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> Heating input 2.5 kW Sensible cooling 11970 Btuh <br /> Heating output 8448 Btuh Latent cooling 5130 Btuh <br />� Temperature rise 13 °F Total cooling 17100 Btuh <br /> Actual air flow 570 cfm Actual air flow 570 cfm <br /> Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh <br /> Static pressure 0.53 in H20 Static pressure 0.53 in H20 <br /> Space thermostat Load sensible heat ratio 0.81 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br />' .'`� ��� ������ 2017-Sep-0708:16:11 <br /> �;;,, �" � R(ght-Suite�Universa1201717.0.23RSU11033 Page4 <br /> ,ft'u��+ .Google DrivelDocumentslSonny'slRyman 6 Plex.rup Calc=MJB Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.