My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19005
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 1:58:54 PM
Creation date
9/17/2018 1:58:46 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19005
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6780 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect Summar Job: Ryman 6 Plex I <br /> I � 1��`I������� � � Byte: DJM 6,2017 <br /> Unif 5 <br /> ' � • e <br /> For: Ryman 6 Plex � - <br /> Dade City,FL <br /> Notes: <br /> � - � a a <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 27 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gdlb <br />' Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 6111 Btuh Structure 8327 Btuh <br /> Ducts 2331 Btuh Ducts 3390 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 8442 Btuh Use manufacturer's data n <br /> Rate/swing muitiplier 0.96 <br /> Infiltration Equipment sensible load 11295 Btuh <br /> nnethod Simplifled Latent Cooling Equipment Load Sizing � <br /> Construction quality Average <br /> Fireplaces 0 Structure 1846 Btuh � <br /> Ducts 814 Btuh i <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1090 1090 Equipment latent load 2660 Btuh i <br /> Uolume(fl) 9693 9693 i <br /> Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh <br /> Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton i <br /> lieating Equipment Summary Cooling Equipment Surnmary I <br /> � <br /> Make Make Carrier ( <br /> Trade 5 KW Trade CARRIER AIR CONDITIONING <br /> PVlodel Cond 24ACB318ABN32 i <br /> AHRI ref Coil FB4.CNP018L ; <br /> AHRI ref 9859025 � <br /> Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> Heating input 2.5 kW Sensible cooling 11970 Btuh <br /> Heating output 8448 Btuh Latent cooling 5130 Btuh � <br /> Temperature rise 13 °F Total cooling 17100 Btuh ! <br /> Actual air flow 570 cfm Actual air flow 570 cfm ! <br /> Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh <br /> Static pressure 0.53 in H20 Static pressure 0.53 in H20 � <br /> Space thermostat Load sensible heat ratio 0.81 <br /> � <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i <br /> . i <br /> • 2017-Sep-07 08:16:11 i <br /> ,�+;�, � �e���t�'�'�� Right-Suite�Universa1201717.0.23 RSU11033 page5 i <br /> ,JB�U�+. .Google DrivelDocuments\Sonny'slRyman 6 Plex.rup Calc=MJB Front Door faces: E <br /> I <br /> I <br /> I I <br />
The URL can be used to link to this page
Your browser does not support the video tag.