My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19010
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 2:02:57 PM
Creation date
9/17/2018 2:02:55 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19010
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6754 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOf2M R405-2014 <br /> ' Florida Department of Business and Professional Regulations <br /> Residential Whole Buildin Performance and Prescri tive Methods <br /> ADDRESS: Permit Number: <br /> Dade C�ty,FL, <br /> iVIANDATORY E2EQUIRIEMENT$See individua(cade sections for fu(I details. <br /> � 401.3 Energy Performance Levet(EPL}display card(Mandatoryj. The buil8ing afficial shali require that an energy pe�farmance levei{EPL} <br /> display card be comp2eted and certified by the builder to be accurate and correct before fina!approval of the building for occupancy.Florlda law <br /> (Section 553.9p85,Florida Statues]requires the EPL display card to be included as an addendum to each saies contract for both presotd and <br /> nonpresoid residentiat buildings.The EPL disptay card confains information indicating ihe energy performance level and efficiencies af camponents <br /> installed in a dwei(ing unit.The t�ui{ding o�cial shaN verify that ilie EPL display card completed and signed by the builder accurately reflects the plans <br /> and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix e. <br /> � R402.A Air leakage(Mandatory). The building lhermal envelope shall be cansfructed fo limit air leakage in accordance with the raquirements of <br /> Sections R402.1 through RA02.4.4. <br /> p R402.4.1 Building thermai enve)ope. The building thermal envelope sha11 comply wiih Sections R402.-4:9 1 a-5i'd-R442.-4:i:2.—The <br /> sealing methods between dissimilar materials shal!atlow for differential expansian and contraction. <br /> � R402.4.1.9 lnstat(ation.The campanents af the building thermat envelope as listed in 7able R4Q2.4.1.1 shall be installed in <br /> accordance with ihe manufacturer's instructians and the criteria listed in Table 402.4.1.1,as applicable to ihe meihod of construction. <br /> Where required by the code officiai,an approved third party shail inspect aA campanenfs and verify compliance. <br /> • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air <br /> cfianges per haur in Ciimate Zones 1 and 2,and 3 sir changes per hour in G{imate Zones 3 through 8.Testing shal!be conducted wllh <br /> a biowar daor at a pressure of 0.2 inches w.g.{50 Pascals).Where required by the code official,tes6ng shall be conducted by an <br /> approved third party.A written repor#of the results of the tesi shall be signed by the party conducfing the tesf and provided ta the code <br /> official.Testing shali be perfarmed at any time after creation of a!i penetrations af#he building therma!envelope. <br /> During testing: <br /> 1.Exterior w{ndows and daors,fireplace and stove doors shaU be closed,but not sealed,beyond the intended weatherstripping ar <br /> other infiltration control measures; <br /> 2.Dampers inciuding exhaust,intake,makeup air,backdraB and ttue dampers sha!!be closed,but not sealed beyond infended <br /> infiltration contro(measutes; <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventitation systems and heat recovery ver�tilafars shali be closed and sealed; <br /> 5.Heafing and cooling systems,if installed at fhe time of the test,sha!!be turned off;and <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully apen. <br /> O l2402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combusiion air. <br /> O R402.4.3 Fenestration a3r leakage!/Uindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm <br /> per square foot(1.5 Lls/m2),and swinging doors na more than 0.5 cfm per square faot(2.6 Uslm2},when tested according ta NFRC 4d0 or <br /> AAMAIWDMAlGSA 10111.S.21A440 by an accredited,independent lahoratory and tisted and labeled by the manuPacturer. <br /> Exception: Site-built windows,skylights and doors. <br /> O R402.4.4 Recessed lighting. Recessed luminaires instailed in the building thermai envelape sha!!be sealed to lim3t air leakage <br /> between condiUoned and uncanditioned spaces.AII recessed luminaires shall be IC-rated and labeled as having an air leakage rate not <br /> more than 2.0 cfm(0.944 L/s}when tested fn accordance with ASTM E 283 at a 1.57 psf(75 Pa}pressure differenfial.Ai)recessed <br /> luminaires shal!he sealed wifh a gasltet or caulk between the housing and the interior wall oc ceiling cavecing. <br /> � R403.1.1 Thermostat provlsion{Mandatory}.At least one thermasiat shaJi be pravided for each separate heating and coaling system. <br /> � R403.1.3 Neat pump supplemenfary heat{14tlandatory}.Heai pumps hauing sugplementary electric-resistance heat shalf heve controls <br /> that,except during defrost,prevent supplemental heaf operation when the heat pump compressor can meet the heating load. <br /> � R403.2.2 Sealing{Mandatory}?II ducts,air handlers,and filter boxes and building cavities that form the primary air containment <br /> passageways for air distribution systems shall be considered ducts and plenum cfiambers,shail be consfructed and sealed in accordance <br /> with Section C403.2.7.2 of fhe Commercia!Provisions af this cade and shaii be shown to meei duct tighiness criferia by post-construction <br /> ar rough-in festing below. <br /> Duct tightness shall be veritJed by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section <br /> 553.99,Florida Sta#utes,or as autharized 6y Florida Statutes,to be"substantialty leak free"by either of the following: <br /> 1 Post-construction test:Total leakage shall be Iess ihan or equal to 4 cfm(113 Vmin)per 100 square feet(9.29 m2}of conditioned 8oar area <br /> whe�tested af a pressure differen#ial of�.7 inches w_g.{25 Pa}actass the entire system,including fhe manufacturer's air hand(er enc{asure.A!{ <br /> register boots shall be taped or oiherwIse sealed during the test. <br /> 2. Rough-in test:Totai leakage shall be tess than or equal ta 4 cfm{113 Llmin)per 100 square feet(9.29 m2)of conditioned floor area when tested <br /> ai a pressure differential of 0.1 inches w.g.(25Pa)across the system,including#he manufacturer's air handler enclosure.A(1 registers shall 6e <br /> taped or otherwise sealed dueing fhe test.)f the air handter is not instalied at the time of the test,tofal leakage shall be less than ar equai ta 3 cfm <br /> {85 Limin}per 9d0 square ieet(9.29 m2}af conditianed floor acea. <br /> F�cce{rtions: <br /> 'f. The totai leakage test ls not cequired for ducts and air handlers located entirely within ihe bullding envelope. <br /> 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. <br /> 9!7l2047 7:51 AM EnergyGauge�USA-FlaRes2Q14 -Sectian R405.4.1 Com Page 1 af 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.