My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19010
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 2:02:57 PM
Creation date
9/17/2018 2:02:55 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19010
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6754 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - -� <br /> i <br /> ` FORM R405-2014 <br /> �fA[�QE4TC?RY REQIJIRE�lIER��'S - (Continued) <br /> � R403.2.3 Buitding Cavitiss{Mandataryj.BuIlding framing cavities shall not be used as ducts or plenums. � <br /> ❑ R403.8 Mechanical system piping lnsulation(Mandatory�. Mechanical system piping capable of carrying fluids above 105°F(41°C) ` <br /> or below 55°F(13°C)shall be insulated to a minirnum of R-3., � <br /> R403.3.1 Protection of piping insulatlon. I <br /> � R403.4.1 Circulating hot water systems(Mandatory). Cireuiafing hot wafer systems sha(I be provided wifh an automafic ar readily j <br /> accessibie manuai switch that can tum off the hot-water circu(ating pump when the system Is not in use, ; <br /> I <br /> � <br /> � R403.4.3 Heaf traps(Mandatory). Storage water fieaters r�ot equipped with integral heat traps and having verfical pipe risers sha! ave <br /> heat traps instailed on aafh the inlets and outlefs.Externai heat traps shat!consist of either a commercia!!y available heat trap or a <br /> downward and upward bend of at least 3"/:inches(89 mm)in the hot water distribution line and cold water line located as close as possible <br /> to the storage tank. . <br /> � R403.d.A Wafer heaEer efficiencies(Mandatoryj. <br /> (� R403.4.4.9 Storage water heater temperature cantrals <br /> . R403.4.A.1.1 AutomaEic contrats. 5ervice water heating sysfems shal!be equipped with automatic temperature cqntrols <br /> capable of adjustment from the lowest to the highest acceptabie temperature seltings for the intended use.The minimum <br /> #emperature setfing eange shat(be from 100"F to 140°F(38°C to 60°C}. <br /> . R403.4.4.1.2 Shut down. A separate switch or a c(early marked circuit breaker shatl be providad to permit the power suppl'sed <br /> to etectric service systems to be turned aff.A separate valve shai(be prnvided to permit the energy supptied to the main burner(s) <br /> of combustion types of service water heating systems ko be tumed off. <br /> p R403.4.4.21Nater heating equIpment. Water heating equipment installed in residential units sha!!meet the minimurn efficiencies of <br /> Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Pravisions,for the type of equipment insfalted. <br /> Equipment used to provide heating funcfions as part of a combination system shall satisfy aII stated requirements far fhe appropriate water � <br /> heafing category. Solar water heaters shalf inet ihe criteria SecUon R403.4.4.2.1. <br /> . R403.4_4.2.3 Salar wafer heaYsng systems.8ofar systems for domestic hot water productian are rated by the annual solar energy <br /> factor of the system.7he solar energy factor of a system shall be determined from the Florida Salar Energy Centet Directory of <br /> Certified Sotar Systems.Solar coI)ectors shali be fested in accordance with!SO S#andard 9806,Test Methods far Solar Ca!lectors, <br /> and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water. <br /> heating systems should meet the following criteria: <br /> 9. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and <br /> 2. Be insfalled af an orientation within 45 degrees of true south. <br /> p R403.5 Mechanicai ventitation(Mandatoryj. The buiiding shall be provided wiFh ventitation thaf ineefs the requirettrents of the <br /> Flarida Suilding Code,Residentia!or FEorida Building Gode,Nlechanicai,as applicabie,ar with ather approved means of ventilation. <br /> Ou2door air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operaking. <br /> p R4q3.6 Neating and cooling equipment(Mandatory). The following sactions are mandafory for cooling and fieating equipment. <br /> 0 R403.6.1 Equipment sizing. Neating and caoiing equipment shatl be sized in accordance with ACGA Manoai S based on the <br /> equipment loads calculated in accordance with ACCA N3anuai.1 or ofher appcoved hea6ng and cooling calculation methodologies, <br /> based on building laads for the direclional orientation of the building.The manufacturer and model number of the outdoor and <br /> , indoor units(if split system}shail be submitted along with the sensibte and tota!cooting capacifies at the design conditions <br /> described in Section R302.1.This code daes not altaw designer safety factors,provisions for future expansion or ather factors <br /> which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation <br />� such as standard kitcfien and ba#firaom exhausf systems. <br /> • R403.6.1.1 Cooiing equipment capacity. Cooiing onty equipment shati be selected sa that its total capacity is nof less than the <br /> calcutated tota!taad,but not more than 1.15 fimes greater than the tota!load calculated according to the procedure selected in <br /> Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding tatent capaciky of the <br /> equipmenf sha(I not be Iess fhan the calcutated latent load. <br /> 9t712017 7:51 AM EnergyGaugeO USA-FlaRes2014 -Sectian R405.4.9 Gom Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.