Laserfiche WebLink
i _ s� <br /> . + • <br /> ��: <br /> . : / . <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation- Residential Performance Method <br /> Project Name: 1791A1 sf ADS Builder Name: Lennar Homes <br /> street: 3168 Moulden Hollow Drive Perm�t ot�ce: �ty`o�ephyrhills <br /> City,State,Zip: ,FL, Permit Number:j � <br /> Owner Lennar Homes .lurisdiction: 6�1600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A z <br /> R= ft <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1817.00 ftZ <br /> 6. Conditioned floor area above grade(ft� 1817 b.N/A R= ftz <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11.Ducts R ftz <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor� Dbl,U=0.54 87.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: • <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> S. Floor Types (1817.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.08 pASS <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �Zk1E,��',�fi� -. <br /> this calculation are in compliance with the Florida Energy specifications covered by this � � _�- -p -. <br /> Code. calculation indicates compliance ' � ,,;�'''• `"'=�.�� �+ <br /> �s . <br /> �ave �/J�G/ with the Florida Energy Code. �•. r�r,��;��;,',;:;�:���;,�O <br /> w< <2 Before construction is completed � - •� '' "`�`"' � <br /> PREPARED BY: _ � ���:-- -^ -- : v <br /> DATE. this building will be inspected for � ��,a C�,_�, � �. <br /> compliance with Section 553.908 *, - �. <br /> I hereby certify that this building,as designed, ' in compliance Florida Statutes. .�_° _ �,� _ <br /> with the Florida Energy Code. G'Qrj' �fi� <br /> 1M11�;, :- <br /> OWNER/AGENT. � BUILDING . FICIAL: <br /> DATE: � �� DATE: - � <br /> - Compliance requires certificatio by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 10/13/2017 1:32 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br /> � <br />