Laserfiche WebLink
? � <br /> _ ��' <br /> . . ;�,:-:. <br /> FORM R405-2014 � - <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1791A1 sf ADS Builder Name: Lennar Homes <br /> street: 3168 Moulden Hollow Drive Permit otfce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner. �ennar Homes ,lurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftz <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1817.00 ftZ <br /> 6. Conditioned floor area above grade(ft� 1817 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 �• R= ft <br /> : <br /> 11.Ducts R ft2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor• Dbl,U=0.54 87.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.56 33.33 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1817.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft� b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ft� 15.Credits Pstat <br /> Glass/Floor Area: 0.079 <br /> Total Proposed Modified Loads: 58.08 pASS <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��.TkIE;STA7,� -. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' __�_ -p <br /> Code. ''�: k==�,;. ..t�._ '� <br /> calculation indicates compliance � _�,, � - �.�, ,,.s+ <br /> �ave �l,�l�rcl� With the Fbrida Ener g y Code. E+ fr�rr,��,,'�:"%.;-;:;�;.,';.��;,�O ` <br /> PREPARED BY: Before construction is completed � `�"'''�� � <br /> DATE. this building will be inspected for � ��jr�t- , ;;� <br /> :� <br /> compliance with Section 553.908 * �� - �.. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � '�,,�, <br /> with the Florida Energy Code. �''Oxj`yyE`�� <br /> OWNER/AGENT: BUILDING OFFICIAL. <br /> DATE. DATE: - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certifed factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br />', test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 10/13/2017 1:32 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br /> I <br />