My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19112
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 2:33:59 PM
Creation date
9/17/2018 2:33:57 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19112
Building Department - Name
LENNAR HOMES LLC
Address
3168 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � • <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRU.CTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1791A1 sf ADS Builder Name: Lennar Homes <br /> street: 3168 Moulden Hollow Drive Permit Office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area I <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ftz ' <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftZ ' <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz � <br /> 4. Number of Bedrooms 4 d.N/A R= ft: I <br /> 10.Ceiling Types (1817.0 sqft.) Insulation Area ' <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 1817 b.N/A R= ftz <br /> z <br /> Conditioned floor area below grade(ftZ) 0 °• R= ft <br /> 11.Ducts R ft2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl,U=0.54 87.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor• Dbl,U=0.56 33.33 ft� 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor. Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems ` <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1817.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftz b. Conservation features <br /> b.N/A R= � ftZ None <br /> c.N/A R= �Z 15.Credits Pstat <br /> Total Proposed Modified Loads: 58.08 pASS <br /> Glass/Floor Area: 0.079 Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �e'Tk�:SxA?,� ., <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��'� r =-_;. .p .. <br /> Code. calculation indicates compliance ���!'�,;,r��'''; `=��'�:������'.�r. . <br /> /" w i t h t h e F lori da Energy Co de. �I. ,r�rri"`�:'%:-::�°�;��`�yti�� <br /> PREPARED BY: �aV� f�GO��'1GVG Before construction is completed i� �� '` `"' <br /> DATE. this building will be inspected for � �-I'���- . `. :� : <br /> � i� <br /> compliance with Section 553.908 *, ��'�,: .- *. ` <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. '� - <br /> with the Florida Ener Code. �G'O �� <br /> 9Y . D�yv�'T� _,. <br /> OWNER/AGENT: BUILDING, FFICIAL: <br /> DATE: DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 10/13/2017 1:32 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.