Laserfiche WebLink
Pro ect Summa Job: 17918 sf ADS <br /> J � Date: 10/13/2017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - • • <br /> For: Lennar Homes <br /> Notes: 40'ADS-2017 <br /> � - • • � <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 23051 Btuh Structure 19615 Btuh <br /> Ducts 2616 Btuh Ducts 2982 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 25667 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 22597 Btuh <br /> Method simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 3041 Btuh <br /> Ducts 534 Btuh � <br /> � Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1817 1817 Equipment latent load 3575 Btuh <br /> , Volume(ft') 15459 15459 <br /> Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 26172 Btuh <br /> Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14FiPX SERIES <br /> Model 14HPX-030-230-21 Cond 14HPX-030-230-21 <br /> AHRI ref 10258600 Coil CBA27UHE-030-230*++TDR <br /> AHRI ref 10258600 <br /> Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER � <br /> Heating input �Sensible cooling 25500 Btuh <br /> Heating output 26400 Btuh @ 47°F Latent cooling 4500 Btuh <br /> Temperature rise 24 °F Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.86 <br /> Capacity balance point= 31 °F <br /> Backup: n/a n/a � <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ,� -�1- wrightsoftm Right-Suite�Universal 2017 17.0.23 RSU05714 2017-Oct-13 13:10:03 <br /> Page 1 <br /> '�� ...CBA27UHE AH's\1791B sf ADS iemplate 2.5ton.rup Calc=MJS Front Door faces:NW <br />