My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19140
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19140
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 9:44:37 AM
Creation date
9/20/2018 9:44:35 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19140
Building Department - Name
LENNAR HOMES LLC
Address
3144 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�. � <br /> FORM R405-2014 <br /> FLCIRIDA ENERGY EFFtCiENCY CODE FOR BU1LDtNG CONSTRUCTION <br /> Florida Department of Business artd Professional Regulation - Residential Performance Method <br /> Project Name: 1841 B sf ADS 3ton Builder Name: Lennar Homes <br /> street: 3144 Moulden Hollow Drive Permit oifice: City of Zephyrhills ' <br /> City,State,Zip: ,FL, Permit Number � � �� <br /> Owner: Lennar Hames Jurisdiction:611 0 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single famity ar mult9ple famity Single-family a.Concrete Block-Int Insul,E�cterior R=4.1 1454.60 ft2 <br /> b.Frame-Wood,Adjacent R=11,0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= �{_ <br /> 4. Number of 8edraoms 4 d•�JA R= ft2 <br /> 5, Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft,) Insulation Area z <br /> , a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Gonditioned fioor area above grade{ft�} 1936 b.NtA R= ft� <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 17.Qucts R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:AtEic,Ref:famity rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ftx <br /> SHGC: SHGC=4.3i <br /> 6. U-Factor Db(,U=0.56 33.33 ftz 12•Gafl<<ng systems 3cBtuthr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor� Dbl,U=0.56 23.00 ftz � <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftx a.Electric Heat Pump 32.8 NSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: p,3pg 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallans <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=O.Q 1936.00 RZ b. Gonservation features <br /> b.NtA R= ft� None <br /> c.N/A R= �' 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Tatal Proposed Modified Loads: 62.94 pASS <br /> Tota! Baseline Loads: 62.65 <br /> I hereby certify that the ptans and specificatians covered by Review af the plans and 0�;'2�:�T�T,� ._ <br /> �- _�� �._. <br /> #his calculation are in compliance with the Florida Energy specifications covered kay this �� ,��. ���h�,, O�, <br /> Code. calculation indicates compliance � ,�`�+',r,;f '' =-` � � <br /> �'�,''��it1�'C` <br /> wi th tFte F l orida Ener g y C ode. `�* {r r i i.�'�:-;,:;::�`:s;,•�,?:.�ti � <br /> PREPARED BY: �Gf.V2 f��l'lG�l Before constructian is completed 'r� � " ' -�. <br /> C7ATE. this building wil!be inspected for � "`1����- - � � : <br /> camp(iance with Section 553.908 ` * •��'�•.-' � �. <br /> l hereb certi that this building,as desi ned,is in com liance Florida Statutes. :� <br /> Y fY 9 P ' "�:�,_` ' . .��,s- . <br /> with the Flarida Energy Cada. - �D`�y�`ifi�` . <br /> OWNER/AGENT: BUlLDlNG OFFlCIAL. <br /> DATE: �* t DATE: ��`� � <br /> - Comp[iance requires certification by e air handler unit manufacturer that the air handler enctosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Gompliance requires an Air Barrier and Insulation Inspectian Checklist in accordance with R442.4.1.1 and an envelope leakage <br /> test report in accardance wi#h R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to autdoors, <br /> tested in accardance with Sectian 803 of RESNET Standards,is not greater than O.Q30 Qn for whole house. <br /> 10/13/2017 1:21 PM EnergyGaugeO USA-FlaRes2q14 Sec#ion R405.4.1 Compliant Software Page 1 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.