FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes <br /> street: 3144 Moulden Hollow Drive Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner. �ennar Homes .lurisdiction:611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz <br />� b.Frame-Wood,Adjacent R=11.0 506.78 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11.Ducts R ft2 <br />� 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 ' <br /> b. U-Factor. DbI,U=0.56 33.33 ftz 12•Cooling systems kBtu/hr Efficiency ; <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor� Dbl,U=0.56 23.00 ftZ I <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft� a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ffZ 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads. 62.94 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 'TI1E S�.q`- <br /> this calculation are in compliance with the Florida Energy specifications covered by thi� ����3 r`_�-r�p � ., <br /> Code. calculation indicates compliance � ��'+'�,,,'''' `''=�:����i+ � <br /> /I with the Florida Energy Code. �i�+ rr�rr"�f%;;;;'-�'�::��;,�� ` <br /> PREPARED BY: �GLV� ��l'IGVL Before construction is completed 'r� � `" ... <br /> DATE. this buildin will be ins ected for �` �� � <br /> 9 p c� -`1f� �-_- .�; . <br /> compliance with Section 553.908 �: �'� : �_ <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. ' �• <br /> with the Florida Energy Code. 9 g p �G'Oj�`y����. ' <br /> OWNER/AGENT: BUILDING O IC L. <br /> DATE. DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. , <br /> 10/13/2017 1:21 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />