Laserfiche WebLink
=�, <br /> , , � � _�� <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes <br /> street: 3144 Moulden Hollow Drive Perrnit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number� <br /> Owner: Lennar Homes Jurisdiction:611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4 1 1454.60 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R_ ff= <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N!A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor Dbl, U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftZ �Z•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.081 <br /> Total Proposed Modified Loads: 62.94 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and _d�T�:$x.��, <br /> _ �: <br /> this calculation are in compliance with the Florida Energy specifications covered bythis 'v�,�� '"�_.�,` 0�,. <br /> Code. calculation indicates compliance �'�'r,,; 't =; � .c�.�s+ <br /> with the Florida Energy Code. F+' �mr�t'%•`===�;,'����"=�„�O� <br /> PREPARED BY: �G�V� f���'IGGI Before construction is completed '� `q�, �'`� "*`� �;` � <br /> DATE: this building will be inspected for � . �e����, - , � �. <br /> compliance with Section 553.908 ' �:, �'�' _ � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � -,: �:� � <br /> with the Florida Energy Code. ��D'{�y�','��� <br /> OWNER/AGENT. BUILDING OFFICIAL: <br /> DATE: DATE: - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 10/13l2017 1:21 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 6 <br />