Laserfiche WebLink
: ` ' <br /> i ..L;� `�'� <br /> i ' � , ±�1�. ' <br /> FORM R405-2014 "- � ' � <br /> FLORIDA ENERGY EFFICIENCY CODE 'FOR BUILDING CONSTRUCTION � <br />' Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 4EHB Elev D/ , ( Builder Name: D�R Ex ess Home�sI" + <br /> Street: . �'�-ZU �Cl���v.,r�������I,s'I'�'2�' Permit Office: (°) � ��1��I <br /> City,State,Zip ephyrhills,FL,r>.7�"�� J� Permit Number: t f (ta <br /> Owner: 1 � Jurisdiction: � (�(�D�) <br /> Design Location: FL,Tampa l County• Pasco(F7orida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=11.0 1285.30 ftz <br /> b.Concrete Block-Int Insul,E�erior R=4.1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz <br /> 4. Number of Bedrooms 5 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1541.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11.Ducts R ftz <br /> 7. Windows(250.0 sqft.) Description Area � a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor• Dbl,U=0.34 210.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor� Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.692 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1541.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features <br /> b.Raised Floor R=19.0 437.00 ftz None -. <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.096 Total Proposed Modified Loads: 78.93 pASS <br /> Total Baseline Loads: 79.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �T�E�7'q�,. - <br /> this calculation are in compliance with the Florida Energy specifications covered by this ���; _ �U�, <br /> Code. calculation indicates compliance � �i,, •,� `.��.�a�O r„ <br /> with the Florida Energy Code. ti rrr„�:,, ;. %;.:;-...,�r„ O� <br /> PREPARED BY: L1h1�Q,,�,�... Before construction is completed r� -µ <br /> -� � ._.fi��:.. � <br /> DATE: io-3o-n this building will be inspected for � gva�� <br /> compliance with Section 553.908 * � ° * <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. � �� <br /> with the Florida Energy Code. ��D�"i'�� <br /> OWNER/AGENTY�����- BUILDING OFFICIAL: <br /> DATE: �'���- DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br />� certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 1 0/30/2017 1 2:41 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />