My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19160
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19160
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 10:46:11 AM
Creation date
9/20/2018 10:46:09 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-19160
Building Department - Name
DR HORTON INC
Address
6720 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; <br /> FORM R405-2014 � �- <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Departmen� of Business and Professional Regul�tion - Residential Performance Method <br /> Project Name: Hayden 4EH6 Elev D , Builder Name: DRH Express Homes <br /> Street: �'�2L� �����,�����{i�5�+�,�� Permit-Office: <br /> City,State,Zip: ephyrhills,FL,r>.7'�'1� J� Permit Number: <br /> Owner: 1 l,� Jurisdiction: <br /> Design Location: FL,Tampa l�Y County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9..Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.30 ftz <br /> b.Concrete Black-Int Insul,Exterior R=4.1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz <br /> 4. Number of Bedrooms � 5 d.N/A R= • ftz <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No- a.Under Attic(Vented) R=30.0 1541.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl, U=0.34 210.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> � SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a. Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.692 ft. `- <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> - a.Electric Cap:50 gallons <br /> 8. Floor Types (1541.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation. R=0.0 1104.00 ft2 b. Conservation features <br /> b.Raised Floor R=19.0 437.00 ftz None <br /> c.N/A R= ftz 15.Credits � Pstat <br /> Total Proposed Modified Loads: 78.93 � A�� <br /> Glass/Floor Area: 0.096 Total Baseline Loads: 79.15 fi <br /> I hereby certify that the plans and specifications covered by Review of the plans and d�'���T,q�,� <br /> this calculation are in compliance with the Florida Energy specifications covered by this - _ � p <br /> %r. .2�c `.r{i <br /> Code. calculation indicates compliance � �,,, �� - ,.� � <br /> with the Florida Energy Code. ti �tr�,.�'%.: =���;:•� �O <br /> •%:;%�..,,�.._. <br /> � PREPARED BY: �'�11�- .,,�„�.. Before construction is completed r� f� '' � <br /> DATE: io-3a-n this buildin will be ins ected for �'�'`� -� <br /> 9 P t9 "��°�j;t ,�•� <br /> , c o m p li ance wi t h Sec tion 5 5 3.9 0 8 * �°.fl * <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� � �,S <br /> with the Florida Energy Code. �'OD��� <br /> OWNER/AGENTr'_ � I�� �/�r>�- � BUILDING OFFICIAL: <br /> DATE: � 1� ��- DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � <br /> 10/30/2017 12:41 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.