My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19188
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19188
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 11:41:21 AM
Creation date
9/20/2018 11:27:36 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19188
Building Department - Name
DR HORTON INC
Address
6711 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- , � <br /> � "� <br /> RM R4 -2 14 '� <br /> FO 05 0 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION - <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> � <br /> Project Name: Cali Elevation D/�-. Builder Name: DRH Expres�mes�'(�s <br /> Street: �'�'� (,�'�, f��M` S'r� Permit Office: ���C� �� <br /> City,State,Zip: Zephyrhills,�� �C�� I �?� Permit Number: � � �f��j <br /> Owner: ��-� Jurisdiction: �{.�g.-(D�((�p� <br /> Design Location: FL,Tampa � � � County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. Number of units,if multiple family , 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types (1828.0 sqft.) � Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1828.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ft2 <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ftz � <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area a.Electric . Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 ,1828.00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.091 <br /> Total Proposed Modified Loads: 59.75 pASS <br /> Total Baseline Loads:. 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and .�THE S?',�?, <br /> •this calculation are in compliance with the Florida Energy specifications covered by this �� ' �O� <br /> �,., <br /> Code. calculation indicates compliance � �,,,r�'�;�� `_^',�� .s+ <br /> with the Florida Ener Code. ti rr,r°"�'��%- `=�'�°���'`� �O <br /> 9Y rr.,, ;;;r•,�.•,,.t� t, <br /> PREPARED BY: L'Ihl�.�.�.. Before construction is completed � �;�^ '� d <br /> DATE: io-ao-n this building will be inspected for � """I;::: �. <br /> �� n <br /> compliance with Section 553.908 * �.. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. j� �� <br /> with the Florida Energy Code. C�D y�','�� <br /> OWNER/AGENT:/ BUILDING OFFICIAL: <br /> DATE: 1 � ( (�� � DATE: - ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as " <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Gln requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Gln for whole house. <br /> 10/30/2017 2:01 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.