Laserfiche WebLink
, ' i <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CORlSTRUCTION� <br /> Florida Department of Business and-Professional Regulation - Residential Performance Method - - ' <br /> Project Name: Cali Elevation D � Builder Name: DRH Express Homes <br /> Street: ���-'I (,�'����1 M��� I t�.��� Permit Office: <br /> City,State,Zip: Zephyrhills, �� �r p � Permit Number: <br /> Owner: ��j�-[/ �i Jurisdiction: <br /> Design Location: FL,Tampa 1 � l County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing " New(From Plans) 9: Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. Number of units,if multiple family 1 c.N/A 2 <br /> R= ft <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11. Ducts R ftz <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12•Cooling systems kBtu/hr Efficiency <br />' SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor. N/A ftz <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1828.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A - R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 59.75 � q�� <br /> Glass/Floor Area: 0.091 Total Baseline Loads: 61.25 ��� <br /> I hereby certify that the plans and specifications covered by Review of the plans and �-�'��E�T,q�,fi <br /> this calculation are in compliance with the Florida Energy specifications covered by this .� �� , ' : � p <br /> Code. calculation indicates compliance �'�j,,,'�� `=_°�.� �„ <br /> w i t h t h e F l o r i d a E n e rgy Co de. ti flttrl�'��.� `='sz��;.�`•�„ O <br /> PREPARED BY: �'►h1�-��,:.. Before construction is completed � - � <br /> i0-3o-17 this buildin will be ins ected for � '���'�` ...J' ,� <br /> DATE: 9 P � I�F�; <br /> e�;�: <br /> compliance with Section 553.908 * �'n ,�. <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. � �,S <br /> with the Florida Energy Code. " �OD y��� <br /> OWNER/AGEN : . � BUILDING O FICIAL: <br /> DATE: r _ DATE: ' ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct.leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 10/30/2017 2:01 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 , <br />� <br />