My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19190
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19190
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 11:41:10 AM
Creation date
9/20/2018 11:32:05 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19190
Building Department - Name
DR HORTON INC
Address
6712 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Com liance Re�1ort Job: <br /> � -�- wrightsoft° p r Date: Oct 10,zo,4 <br /> Entire House By� <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-8153399 License:CAC033669 <br /> � • ' • • <br /> For: DR Horton <br /> Lot 2 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> • . • • • <br /> Design Conditions , <br /> Outdoor design DB: 91.2°F ,Sensible gain: 21334 Btuh Entering coil DB: 76.1°F <br /> - Outdoor design WB: 77.1°F Latent gain: 2877 Btuh Entering coil WB: 63.0°F <br /> Indoor design DB: 75.0°F Total gain: 24211 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Pertormance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030**`*A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23532 Btuh 110%of load <br /> Latent capacity: 3786 Btuh 132%of load <br /> Total capacity: 27318 Btuh 113%of load SHR: 86% � <br /> . • • <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 20312 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F , <br />� Manufacturer's Performance Data at Actual Design Conditions - <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030""'`*A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25625 Btuh 126%of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F I <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 6.4 kW 108%of load Temp. rise: 20 °F <br /> Meets are all requirements of ACCA Manual S. <br /> .�. wri htsoft° 2017-Oct-3011:07�43 <br /> 1, 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 <br /> �� ..on\W rightsoft Files\Express homes�Aria 4EAB.rup Calc=MJ8 House taces: N <br />
The URL can be used to link to this page
Your browser does not support the video tag.